LONOKE, AR —
OSHA Inspection: REMINGTON ARMS COMPANY, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of REMINGTON ARMS COMPANY, INC. in 2592 HWY. 15 N, LONOKE, AR 72086 (NAICS 332992). OSHA activity number 339142846.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REMINGTON ARMS COMPANY, INC.
- Site address
- 2592 HWY. 15 N
- City
- LONOKE
- State
- AR
- ZIP
- 72086
- Mailing
- 2592 HWY. 15 N, LONOKE, AR 72086
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332992
- Employees
- 1150
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.1025 H01
- Issued
- Dec 3, 2013
- Abate by
- Dec 18, 2013
- Penalty
- Initial $27,500 · Current $15,000 Reduced
General-duty citation text
29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead: The Remington Arms Co., Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1025(h)(1) which was contained in OSHA inspection number 314352329, citation number 1, item number 7a and was affirmed as a final order on October 15, 2012, with respect to a workplace located at 14 Hoefler Avenue, Ilion, New York. On or about June 25, 2013, at Remington Arms Co., Inc., the employer did not ensure employees processing lead were not exposed to contaminated surfaces. Instance a) On or about June 25, 2013, at the showers throughout the facility, the employer did not ensure employees were not exposed to lead contaminated surfaces while showering. Lead screening using LeadCheck Swab tips on shower thresholds, floors and walls indicated a hazardous level of lead present. This created a condition for employees to be exposed to inhalation ingestion hazards associated with airborne or accumulative lead dust on surfaces. Instance b) On or about June 25, 2013, at the center fire lead "extruder" area, the employer did not ensure employees were not exposed to lead contaminated surfaces while processing lead from solid to liquid to wire rope and cutting and scraping meltdown pot. Laboratory results indicated a lead concentration ranging from 0.0324 milligrams per cubic meter to 0.3135 milligrams per cubic meter for personal air samples collected in the work area. Lead screening using LeadCheck Swab tips on floor area and stair railing at and around the extruder machinery indicated a hazardous level of lead present. This created a condition for employees to be exposed to inhalation ingestion hazards associated with airborne or accumulative lead dust on surfaces.
Recent events (2)
- — I (S) $15000
- — Z (R) $27500
More inspections at Remington Arms Company, INC.