Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: RETTERBUSH FIBERGLASS CORP.

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of RETTERBUSH FIBERGLASS CORP. in 719 LONG DRIVE, PIQUA, OH 45356 (NAICS 326199). OSHA activity number 339143109.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Retterbush Fiberglass Corp. for free Get an email when a new federal OSHA severe-injury report for Retterbush Fiberglass Corp. is published. One employer, no account, unsubscribe in one click.
Site address
719 LONG DRIVE
City
PIQUA
State
OH
ZIP
45356
Mailing
P.O. BOX 207, PIQUA, OH 45356
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
26
Ownership type
Private (A)

6 citations on file for this inspection.

1910.147 C07 III A

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 16, 2013
Abate by
Jan 13, 2014
Penalty
Initial $3,500 · Current $1,700 Reduced
29 CFR 1910.147(c)(7)(iii)(A): Retraining shall be provided for all authorized and affected employees whenever there is a change in their job assignments, a change in machines, equipment or processes that present a new hazard, or when there is a change in the energy control procedures:    (a)  Employees were not retrained on the energy control program, in that employees thought it was acceptable to lock out the hydraulic presses by attaching locks to the disconnects and then hanging the keys to the locks on hooks close to the disconnects.       In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • · I (S) $1700
  • · Z (S) $3500

1910.147 D04 II

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 16, 2013
Abate by
Jan 13, 2014
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.147(d)(4)(ii):  Lockout devices, where used, shall be affixed in a manner that will hold the energy isolating devices in a safe or off position is prohibited:      (a)  The lockout devices (locks) attached to the disconnects on the hydraulic presses were not attached in a manner that could be relied on to hold the electrical disconnects in the off position, in that the keys to the lockout devices were left hanging on a hook by the disconnects.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3500

1910.147 C06 I

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 16, 2013
Abate by
Jan 13, 2014
Penalty
Initial $7,000 · Current $3,000 Reduced
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed:      (a)  There was no annual review of the energy control program.       Retterbush Fiberglass Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 110528, citation number 2, item number 2 and was affirmed as a final order on March 26, 2012, with respect to a workplace located at 719 Long Drive, Piqua, Ohio.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • · I (S) $3000
  • · Z (R) $7000

1910.147 D03

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 16, 2013
Abate by
Jan 13, 2014
Penalty
Initial $7,000 · Current $3,000 Reduced
29 CFR 1910.147(d)(3): Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):      (a)  Employees cleaned the molds on the hydraulic presses without isolating the electrical energy source.       Retterbush Fiberglass Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 110528, citation number 1, item number 2a and was affirmed as a final order on March 26, 2012, with respect to a workplace located at 719 Long Drive, Piqua, Ohio.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • · I (S) $3000
  • · Z (R) $7000

1910.147 D04 I

Repeat Gravity 5 2 instances 2 exposed
Issued
Dec 16, 2013
Abate by
Jan 13, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees:    (a)  Employees cleaned the molds on the hydraulic presses without first affixing a lockout device to the electrical energy isolating device.   Retterbush Fiberglass Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 110528, citation number 1, item number 2b and was affirmed as a final order on March 26, 2012, with respect to a workplace located at 719 Long Drive, Piqua, Ohio.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • · I (R) $0
  • · Z (R) $0

1910.147 C05 II D

Other-than-serious 2 instances 2 exposed
Issued
Dec 16, 2013
Abate by
Jan 13, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(ii)(D): Identifiable. Lockout devices and tagout devices shall indicate the identity of the employee applying the device(s).  (a)    The locks used by authorized employees to attach to the disconnects, did not identify the name of the employee applying the lock.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Retterbush Fiberglass Corp.'s full OSHA safety record →