Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WINONA MANOR HEALTH & REHABILITATION CENTER

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of WINONA MANOR HEALTH & REHABILITATION CENTER in 627 MIDDLETON, WINONA, MS 38967 (NAICS 623110). OSHA activity number 339143430.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Winona Manor Health & Rehabilitation Center — free Get an email when a new federal OSHA severe-injury report for Winona Manor Health & Rehabilitation Center is published. One employer, no account, unsubscribe in one click.
Site address
627 MIDDLETON
City
WINONA
State
MS
ZIP
38967
Mailing
627 MIDDLETON, WINONA, MS 38967
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
623110
Employees
111
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 6, 2013
Abate by
Sep 23, 2013
Penalty
Initial $2,430 · Current $1,458 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.   (a) Job Site - On or about July 16, 2013 specific procedures for locking out stove, oven, washers, dryers and air conditioning units were not developed and implemented.
Recent events (2)
  • — I (S) $1458
  • — Z (S) $2430

1910.303 F02

Other-than-serious 1 instance 1 exposed
Issued
Aug 6, 2013
Abate by
Aug 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:   (a)  Laundry Room - On or about June 16, 2013 the electrical disconnect switches for washer and dryer units were not labeled to indicate what each disconnect controlled.
Recent events (1)
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 2 exposed
Issued
Aug 6, 2013
Abate by
Aug 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:   (a) Laundry Room - On or about June 26, 2013 the circuit breaker box powering the air conditioning unit was blocked.
Recent events (1)
  • — Z (O) $0

View Winona Manor Health & Rehabilitation Center's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339143430.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.