PHILADELPHIA, PA —
OSHA Inspection: JDR CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JDR CONSTRUCTION in 1900 SPRING GARDEN STREET, PHILADELPHIA, PA 19130 (NAICS 238140). OSHA activity number 339145146.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JDR CONSTRUCTION
- Site address
- 1900 SPRING GARDEN STREET
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19130
- Mailing
- 2429 FEDERAL STREET, PHILADELPHIA, PA 19146
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 9
- Ownership type
- A
Citations
11 citations on file for this inspection.
1926.451 B01
- Issued
- Nov 4, 2013
- Abate by
- Nov 8, 2013
- Penalty
- Initial $2,800 · Current $1,540 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports. a) Jobsite: 1900 Spring Garden St, Philadelphia, PA - Scaffold. On or about 6/24/13, the fourth working platform on the supported tubular welded frame scaffold was missing planks. Employees were performing brick pointing and washing activities from the fourth working platform approximately 26 feet above ground level.
Recent events (3)
- — C (S) $2800
- — F (S) $1540
- — Z (S) $2800
1926.451 B05 I
- Issued
- Nov 4, 2013
- Abate by
- Nov 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length extended over its support more than 12 inches, and was not designed and installed so that the cantilevered portion of the platform was able to support employees and/or materials without tipping, or had guardrails which blocked employee access to the cantilevered end. a) Jobsite: 1900 Spring Garden St, Philadelphia, PA - Scaffold. On or about 6/24/13, the cantilevered portion of the platforms on the supported tubular welded frame scaffold extended more than 12 inches over their support which exposed the employees to tipping hazards. Employees were performing brick pointing and washing activities from the outrigger section on the 5th working platform, approximately 32 feet above ground level, and from the 4th working platform, approximately 26 feet above ground level.
Recent events (3)
- — C (S) $0
- — F (S) $0
- — Z (S) $0
1926.451 B03
- Issued
- Nov 4, 2013
- Abate by
- Nov 8, 2013
- Penalty
- Initial $2,800 · Current $1,540 Reduced
General-duty citation text
29 CFR 1926.451(b)(3): Except as provided in paragraphs (b)(3)(i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling. a) Jobsite: 1900 Spring Garden St, Philadelphia, PA - Scaffold. On or about 6/24/13, employees were exposed to fall hazards while working from a supported tubular welded frame scaffold with a platform that was 3 feet 10 inches from the face of work. Employees were performing brick pointing and washing activities from the 4th working platform, approximately 26 feet above ground level.
Recent events (3)
- — C (S) $2800
- — F (S) $1540
- — Z (S) $2800
1926.451 C02 II
- Issued
- Nov 4, 2013
- Abate by
- Nov 8, 2013
- Penalty
- Initial $2,000 · Current $1,100 Reduced
General-duty citation text
29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: a) Jobsite: 1900 Spring Garden St, Philadelphia, PA - Scaffold. On or about 6/24/13, a footing of the supported tubular welded frame scaffold stood on the corner of a stack of three bowed and unevenly positioned pieces of mudsills. Employees were performing brick pointing and washing activities from the outrigger of the 5th working platform, approximately 32 feet above ground level, and from the 4th working platform, approximately 26 feet above ground level.
Recent events (3)
- — C (S) $2000
- — F (S) $1100
- — Z (S) $2000
1926.451 E01
- Issued
- Nov 4, 2013
- Abate by
- Nov 8, 2013
- Penalty
- Initial $2,000 · Current $1,100 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): A means of access for scaffold platforms more than 2 feet (0.6 m) above or below a point of access, such as portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used. a) Jobsite: 1900 Spring Garden St, Philadelphia, PA - Scaffold. On or about 6/24/13, a safe means of access was not provided for employees working from the supported tubular welded frame scaffold. Employees were performing brick pointing and washing activities from the outrigger of the 5th working platform, approximately 32 feet above ground level, and from the 4th working platform, approximately 26 feet above ground level, and accessed the scaffold via the rungs on the integral prefabricated access frames.
Recent events (3)
- — C (S) $2000
- — F (S) $1100
- — Z (S) $2000
1926.451 F07
- Issued
- Nov 4, 2013
- Abate by
- Nov 8, 2013
- Penalty
- Initial $2,000 · Current $1,100 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees selected by, and under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. a) Jobsite: 1900 Spring Garden St, Philadelphia, PA - Scaffold. On or about 6/24/13, no competent person supervised or directed the erection and alteration of the supported tubular welded frame scaffold in a manner that ensured the safety of the workers to the extent that was feasible. Employees used scaffold to perform brick pointing and washing activities with the rear leg of the end frame on the west end cut out to accommodate its placement over the staircase at the front of the building.
Recent events (3)
- — C (S) $2000
- — F (S) $1100
- — Z (S) $2000
1926.451 A01
- Issued
- Nov 4, 2013
- Abate by
- Nov 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(a)(1): Each scaffold and scaffold component was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it. a) Jobsite: 1900 Spring Garden St, Philadelphia, PA - Scaffold. On or about 6/24/13, a component on the supported tubular welded frame scaffold was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it. Employees were performing brick pointing and washing activities from the outrigger of the 5th working platform, approximately 32 feet above ground level, and from the 4th working platform, approximately 26 feet above ground level.
Recent events (3)
- — C (S) $0
- — F (S) $0
- — Z (S) $0
1926.451 F04
- Issued
- Nov 4, 2013
- Abate by
- Nov 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(4): Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired. a) Jobsite: 1900 Spring Garden St, Philadelphia, PA - Scaffold. On or about 6/24/13, the damaged and weakened rear leg on the west end of the supported tubular welded frame scaffold was not immediately repaired or replaced, braced to support its own weight or 4 times the maximum intended load, or removed from service until repaired.
Recent events (3)
- — C (S) $0
- — F (S) $0
- — Z (S) $0
1926.451 G01 VII
- Issued
- Nov 4, 2013
- Abate by
- Nov 8, 2013
- Penalty
- Initial $2,800 · Current $1,540 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee was not protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Jobsite: 1900 Spring Garden St, Philadelphia, PA - Scaffold. On or about 6/24/13, employees were not provided with a fall protection system while working from a supported tubular welded frame scaffold. Employees performed brick pointing and washing activities and were exposed to fall hazards while working from the outrigger on the 5th working platform, approximately 32 feet above ground level, and from the 4th working platform, approximately 26 feet above ground level
Recent events (3)
- — C (S) $2800
- — F (S) $1540
- — Z (S) $2800
1926.454 A
- Issued
- Nov 4, 2013
- Abate by
- Nov 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work on a scaffold be trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used, and to understand the procedures to control or minimize those hazards. a) Jobsite: 1900 Spring Garden St, Philadelphia, PA - Scaffold. On or about 6/24/13, JDR Construction did not train their employees to recognize the hazards that are present when working from a supported tubular welded frame scaffold, and to understand the procedures to control or minimize those hazards.
Recent events (3)
- — C (S) $0
- — F (S) $0
- — Z (S) $0
1926.20 B01
- Issued
- Nov 4, 2013
- Abate by
- Nov 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain an accident prevention program as may be necessary to comply with the General safety and health provisions covered in 29 CFR 1926.20. a) Jobsite: 1900 Spring Garden St, Philadelphia, PA - Scaffold. On or about 6/24/13, JDR Construction did not develop and implement an accident prevention program to help protect their employees from hazardous working conditions.
Recent events (3)
- — C (S) $0
- — F (S) $0
- — Z (S) $0
More inspections at JDR Construction
View JDR Construction's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339145146.