Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: CONTECH CONTROL SERVICES

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of CONTECH CONTROL SERVICES in 8280 SHELDON RD., CHANNELVIEW, TX 77530 (NAICS 541330). OSHA activity number 339149940.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Contech Control Services for free Get an email when a new federal OSHA severe-injury report for Contech Control Services is published. One employer, no account, unsubscribe in one click.
Site address
8280 SHELDON RD.
City
CHANNELVIEW
State
TX
ZIP
77530
Mailing
2801 SENS ROAD, LA PORTE, TX 77571
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541330
Employees
59
Ownership type
Private (A)

5 citations on file for this inspection.

1910.146 C09 I

Other-than-serious 1 instance 4 exposed
Issued
Nov 27, 2013
Abate by
Dec 4, 2013
Penalty
Initial $4,900 · Current $4,900
29 CFR 1910.146(c)(9)(i): Each contractor who was retained to perform permit space entry operations did not obtain any available information regarding permit space hazards and entry operations from the host employer:    The employer does not obtain any available information regarding permit space hazards and entry operations from the host employer.  This violation was occurred on or about June 14, 2013, and at times prior thereto, in the Methanol Convertor Reactor 7001 where employees were exposed to atmospheric hazards without the employer having obtained any available information regarding permit space hazards from the host employer.     Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all information regarding permit space hazards and entry operations are obtained from the host employer.
Recent events (2)
  • · I (O) $4900
  • · Z (S) $4900

1910.146 D02

Other-than-serious 1 instance 3 exposed
Issued
Nov 27, 2013
Abate by
Dec 4, 2013
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1910.146(d)(2): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not identify and evaluate the hazards of permit spaces before employees entered:    The employer does not identify and evaluate the hazards of permit spaces before employees enter them.  This violation occurred on or about June 14, 2013, and at times prior thereto, in the Methanol Convertor Reactor 7001 where employees were exposed to an atmospheric hazard when working in a permit space without the employer identifying and evaluating all hazards of the permit space.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all hazards of permit spaces are identified and evaluated prior to employees making entry.
Recent events (2)
  • · I (O) $0
  • · Z (S) $4900

1910.146 D03 IV

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 27, 2013
Abate by
Dec 4, 2013
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1910.146(d)(3)(iv): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement the means, procedures, and practices necessary for safe permit entry operations.    The employer does not implement the means, procedures, and practices necessary for safe permit entry operations to eliminate or control atmospheric hazards.  This violation was occurred on or about June 14, 2013, and at times prior thereto, in the Methanol Convertor Reactor 7001 where employees were exposed to an atmospheric hazard while working in the reactor without developing and implementing the means, procedures, and practices necessary for safe permit entry operations.       Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that permit spaces are purged, inerted, flushed, or ventilated as necessary to eliminate or control atmospheric hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $4900

1910.146 F04

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Nov 27, 2013
Abate by
Dec 4, 2013
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1910.146(f)(4): The entry permit that documented compliance and authorized entry to a permit space did not identify the authorized entrants within the permit space by name or by such other means:  The employer does not identify the names of the authorized entrants on entry permits.  This violation was occurred on or about June 14, 2013, and at times prior thereto, in the Methanol Convertor Reactor 7001 where employees were exposed to an accountability hazard while working in the reactor, a permit required confined space, without being identified by name or other such means on the entry permit.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that authorized entrants are identified by name or other such means on the entry permits.
Recent events (2)
  • · I (S) $0
  • · Z (S) $4900

1910.1200 H01

Other-than-serious 1 instance 3 exposed
Issued
Nov 27, 2013
Abate by
Dec 4, 2013
Penalty
Initial $4,900 · Current $4,900
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    The employer does not provide employees effective information and training on hazardous chemicals in their work areas.  This violation occurred on or about June 14, 2013, and at times prior thereto, in the Methanol Convertor Reactor 7001 where employees were exposed to an atmospheric hazard when making entry and working in the reactor, a permit required confined space, without having been provided effective information and training on the health hazards in their work area.      Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that employees are provided effective information and training on hazardous chemicals in their work area.
Recent events (2)
  • · I (O) $4900
  • · Z (S) $4900

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339149940.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.