Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FUSION INDUSTRIES, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of FUSION INDUSTRIES, LLC in 16710 GATOR ROAD, FORT MYERS, FL 33912 (NAICS 327991). OSHA activity number 339151250.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fusion Industries, LLC — free Get an email when a new federal OSHA severe-injury report for Fusion Industries, LLC is published. One employer, no account, unsubscribe in one click.
Site address
16710 GATOR ROAD
City
FORT MYERS
State
FL
ZIP
33912
Mailing
16710 GATOR ROAD, FORT MYERS, FL 33912
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327991
Employees
70
Ownership type
A

5 citations on file for this inspection.

1910.242 B

Serious Gravity 5 1 instance 15 exposed
Issued
Oct 29, 2013
Abate by
Nov 25, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:     a. At the facility located on 16710 Gator Road, Ft. Myers, FL, employees are exposed the the physical hazards associated with the use of compressed air for cleaning purposes. The air line meassured 100 psi, on or about 07/16/2013.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.1200 H01

Serious Gravity 5 1 instance 15 exposed
Issued
Oct 29, 2013
Abate by
Nov 25, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced

Hazardous substances 173017409010

29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:   a. At the facility located on 16710 Gator Road, Ft. Myers, FL, employees are exposed the the health and physical hazards associated with the use of chemicals such as, but not limited to, silica and methylene chloride. Employees are subject to skin burns and/or irritation. No training had been provided, on or about 06/26/2013.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.95 C01

Other-than-serious 1 instance 15 exposed
Issued
Oct 29, 2013
Abate by
Dec 1, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average (TWA)sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:   a) At the establishment located on 16710 Gator Road, Ft. Myers, FL employees performing activities such as; cutting, grinding and buffing granite material were exposed to high levels of noise. An employee was exposed during the 447 minute monitoring period to 102.7 percent of the allowable daily exposure, on or about, 07/16/2013. This dose is equivalent to 90.7 dbA as an 8-hour TWA. No hearing conservation had been established, on or about, 06/26/2013.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 C01

Other-than-serious 1 instance 2 exposed
Issued
Oct 29, 2013
Abate by
Dec 17, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 1730

29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  a. At the facility located on 16710 Gator Road, Ft. Myers, FL, for employees required to use a half face, Sundstrom, respirator with dual organic vapor and pre-filter cartridges, as observed on or about, 06/26/2013.  The respirator was used while spraying an adhesive product containing chemicals such as, but not limited to, methylene chloride. The employer had not established and implemented a written respirator program to include elements such as, but not limited to: medical evaluations, fit-testing and training of employees.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1052 D02

Other-than-serious 1 instance 15 exposed
Issued
Oct 29, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 1730

29 CFR 1910.1052(d)(2): The employer did not perform initial monitoring to determine each employee's exposure to methylene chloride: a. At the facility located on 16710 Gator Road, Ft. Myers, FL, employee exposed the the health and physical hazards associated with methylene chloride, while performing, an adhesive, spray application. No monitoring had been performed, on or about 06/26/2013.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Fusion Industries, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339151250.