MENASHA, WI —
OSHA Inspection: AROUND THE CLOCK CLEANERS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AROUND THE CLOCK CLEANERS in 1486 KENWOOD DR, MENASHA, WI 54952 (NAICS 561720). OSHA activity number 339153439.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AROUND THE CLOCK CLEANERS
- Site address
- 1486 KENWOOD DR
- City
- MENASHA
- State
- WI
- ZIP
- 54952
- Mailing
- 1486 KENWOOD DR, MENASHA, WI 54952
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561720
- Employees
- 23
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.37 A01
- Issued
- Aug 23, 2013
- Abate by
- Sep 23, 2013
- Penalty
- Initial $1,360 · Current $680 Reduced
General-duty citation text
29 CFR 1910.37(a)(1): Exit routes were not kept free of explosive or highly flammable furnishings or other decorations: a) The liquefied petroleum gas tank containers were kept outside next to the exit doorway that leads to the storeroom. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED.
Recent events (2)
- — I (S) $680
- — Z (S) $1360
1910.110 F06 II
- Issued
- Aug 23, 2013
- Abate by
- Sep 23, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.110(f)(6)(ii): Containers were not stored in a suitable enclosure or otherwise protected against tampering: a) The liquefied petroleum gas tank containers were stored outside the exit door outside the storeroom and not protected against tampering. ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Aug 23, 2013
- Abate by
- Sep 23, 2013
- Penalty
- Initial $1,360 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) The employees were exposed to tubes, wires, and other mechanical items when the black Aztec ProScrub in the storeroom was being operated without the back panel per the manufacturer's owner's manual. ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $1360
1910.305 G01 IV A
- Issued
- Aug 23, 2013
- Abate by
- Sep 23, 2013
- Penalty
- Initial $1,360 · Current $680 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) In the storeroom there was a relocatable power tap used to charge the Lester Lestronic II Golf Cart Lift scrubber machine. ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
- — I (S) $680
- — Z (S) $1360
1910.334 A02 I
- Issued
- Aug 23, 2013
- Abate by
- Sep 23, 2013
- Penalty
- Initial $2,040 · Current $1,020 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): a) The flexible electrical cords on the swing machine scrubber in the Chevy Van were taped. b) The flexible electrical cords on the Lester Lestronic II Golf Cart Lift scrubber in the storeroom were taped. c) The back guards were not in place on the black Aztec ProScrub in the storeroom and was not removed from service. ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
- — I (S) $1020
- — Z (S) $2040
1910.334 A02 II
- Issued
- Aug 23, 2013
- Abate by
- Sep 3, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service and an employee was using it before repairs and tests necessary to render the equipment safe were made: a) The flexible electrical cords on the swing machine scrubber in the Chevy Van were taped, not safe, and not removed from service. b) The flexible electrical cords on the red scrubber in the storeroom were taped, not safe, and not removed from service. ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 F05 II
- Issued
- Aug 23, 2013
- Abate by
- Sep 9, 2013
- Penalty
- Initial $1,020 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: a) In the storeroom the Tough on Grease container was not labeled. b) In the worksites the bleach container was not labeled. ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $1020
1910.1200 G08
- Issued
- Aug 23, 2013
- Abate by
- Sep 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not ensure that material safety data sheets were readily accessible to the employees in their work area during each work shift: a) The employer maintained the MSDS sheet locked in the office and employees were not able to access them when they needed to. ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0