GROVE CITY, OH —
OSHA Inspection: CONTRACT LUMBER SOUTH
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CONTRACT LUMBER SOUTH in 1412 PINNACLE CLUB DRIVE, GROVE CITY, OH 43123 (NAICS 236115). OSHA activity number 339153496.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONTRACT LUMBER SOUTH
- Site address
- 1412 PINNACLE CLUB DRIVE
- City
- GROVE CITY
- State
- OH
- ZIP
- 43123
- Mailing
- 4975 HENDRON ROAD, GROVEPORT, OH 43125
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.405 A02 II I
- Issued
- Aug 26, 2013
- Abate by
- Sep 5, 2013
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables shall be protected from damage. Sharp corners and projections shall be avoided. Flexible cords and cables may pass through doorways or other pinch points, if protection is provided to avoid damage. a. On June 25, 2013, employees were using an extension cord that was damaged. The cord was being used to energize a hand power saw. The employees were exposed to a contact hazard with electrical current.
Recent events (3)
- — C (S) $2000
- — Z (S) $2000
- — D (S) $0
1926.405 G02 IV
- Issued
- Aug 26, 2013
- Abate by
- Sep 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws. a. On June 25, 2013, the strain relief was damaged and the wires were visible. The extension cord was being used to power an electric hand saw.
Recent events (3)
- — C (S) $0
- — Z (S) $0
- — D (S) $0
1926.501 B13
- Issued
- Aug 26, 2013
- Abate by
- Sep 13, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. a. On June 25, 2013, three employees were working on the top plate of a two story, single family home without fall protection. The employees were exposed to a fall hazard.
Recent events (3)
- — C (S) $2800
- — Z (S) $2800
- — D (S) $0
1926.503 C03
- Issued
- Aug 26, 2013
- Abate by
- Sep 5, 2013
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.503(c)(3): Inadequacies in an affected employee's knowledge or use of fall protection systems or equipment indicate that the employee has not retained the requisite understanding or skill. Note: The following appendices to subpart M of this part serve as non-mandatory guidelines to assist employers in complying with the appropriate requirements of subpart M of this part. [59 FR 40738, Aug. 9, 1994; 60 FR 5131, Jan. 26, 1995] a. Employees working on the top plate did not demonstrate retention of requisite knowledge for fall protection. The employees were exposed to a fall hazard.
Recent events (3)
- — C (S) $2000
- — Z (S) $2000
- — D (S) $0
1926.1051 A
- Issued
- Aug 26, 2013
- Abate by
- Sep 5, 2013
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1051(a): A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided. a. On June 25, 2013, there were three employees climbing the framework of the house to gain access to the top plate and the trusses. The employees did not have a means off access or egress that complied with this standard, thereby exposing the employees to a fall hazard.
Recent events (3)
- — C (S) $2000
- — Z (S) $2000
- — D (S) $0
More inspections in this industry (NAICS 236115)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339153496.