PLANTSVILLE, CT ·
OSHA Inspection: A & A SURPLUS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of A & A SURPLUS, INC. in 389 MARION AVENUE, PLANTSVILLE, CT 06479 (NAICS 423840). OSHA activity number 339154015.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A & A SURPLUS, INC.
- Site address
- 389 MARION AVENUE
- City
- PLANTSVILLE
- State
- CT
- ZIP
- 06479
- Mailing
- P.O. BOX 302, PLANTSVILLE, CT 06479
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423840
- Employees
- 11
- Ownership type
- Private (A)
Citations
10 citations on file for this inspection.
1910.110 F02 I
- Issued
- Aug 8, 2013
- Abate by
- Sep 25, 2013
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1910.110(f)(2)(i): LP gas container(s) in storage were not located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons: Outside of Building: On, or about, June 28, 2013, a cage used to store propane cylinders was located along the side of the building where vehicular traffic was present and was not protected against being struck.
Recent events (2)
- · I (S) $840
- · Z (S) $1200
1910.176 B
- Issued
- Aug 8, 2013
- Abate by
- Sep 25, 2013
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: Warehouse: On, or about, June 28, 2013, single pieces or small bundles of rack components were stored in with larger, bundled loads. The single pieces/small bundles were not as secure as the large bundles and could create a hazard to employees working around the storage area and walking in the main aisle.
Recent events (2)
- · I (S) $1400
- · Z (S) $2000
1910.252 B02 III
- Issued
- Aug 8, 2013
- Abate by
- Sep 25, 2013
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: Warehouse: On, or about, June 28, 2013, welding screens were not routinely used when welding operations were conducted adjacent to the main aisle in the warehouse.
Recent events (2)
- · I (S) $840
- · Z (S) $1200
1910.303 B02
- Issued
- Aug 8, 2013
- Abate by
- Sep 25, 2013
- Penalty
- Initial $1,600 · Current $1,120 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Warehouse: On, or about, June 28, 2013, a microwave oven, water cooler and radio were energized through a relocatable power tap that was lying on the floor.
Recent events (2)
- · I (S) $1120
- · Z (S) $1600
1910.305 G01 IV
- Issued
- Aug 8, 2013
- Abate by
- Sep 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv): Warehouse: On, or about, June 28, 2013, a microwave oven was energized through an extension cord that was energized through a relocatable power tap.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 B07 I
- Issued
- Aug 8, 2013
- Abate by
- Sep 25, 2013
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: A. Warehouse: On, or about, June 28, 2013, an opening was left in front of the GE 480 volt main distribution panel located under the elevated platform near the shipping desk and main work area. B. Storage Area: On, or about, June 28, 2013, a cover was not installed on a section of raceway located above the main service entrance enclosure.
Recent events (2)
- · I (S) $1400
- · Z (S) $2000
1910.303 G01 II
- Issued
- Aug 8, 2013
- Abate by
- Sep 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: A. Warehouse, Shipping desk area: On, or about, June 28, 2013, boxes, trash and other items were stored in front of the main panel for the main electrical disconnect enclosure. B. Storage Area: On, or about, June 28, 2013, a pallet of material was stored in front of the GE main service entrance enclosure located along the main aisle.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1200 E01
- Issued
- Aug 8, 2013
- Abate by
- Sep 25, 2013
- Penalty
- Initial $1,600 · Current $1,120 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: Warehouse: On, or about, June 28, 2013, the company had not developed and implemented a written hazard communication program to provide information and training to employees who working with chemicals and hazard materials such as, but not limited to, propane, paints, thinners and welding rods.
Recent events (2)
- · I (S) $1120
- · Z (S) $1600
1910.178 A06
- Issued
- Aug 8, 2013
- Abate by
- Sep 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates or markings were not maintained in a legible condition: Warehouse: On, or about, June 28, 2013, identification plates provided on the following forktrucks were no longer legible: A. Green Mitsubishi. B. Komatsu.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.178 P01
- Issued
- Aug 8, 2013
- Abate by
- Sep 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): Warehouse: On, or about, June 28, 2013, the solid weather cover provided on the Green Mitsubishi forktruck did not allow the operator to see through the overhead guard when landing or retrieving overhead loads.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 423840)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339154015.