Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NEW SYSTEM DEMOLITION EXCAVATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NEW SYSTEM DEMOLITION EXCAVATION in 1321 NAYLOR COURT, NW, WASHINGTON, DC 20001 (NAICS 237110). OSHA activity number 339155301.

Watch NEW System Demolition Excavation — free Get an email when a new federal OSHA severe-injury report for NEW System Demolition Excavation is published. One employer, no account, unsubscribe in one click.
Site address
1321 NAYLOR COURT, NW
City
WASHINGTON
State
DC
ZIP
20001
Mailing
3127 MARTIN LUTHER KING AVENUE, SE, WASHINGTON, DC 20032
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c):  a) West Side of the Building - A laborer was entering unprotected 10 feet deep excavation to check water discharge from an existing manhole by stepping down onto a ladder in the excavation exposing him to a potential cave-in  hazard, on or about 06/27/13.  Abatement Documentation Required
Recent events (1)
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2400.00 · Current $2400.00
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder�s length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) West Side of the Building - A laborer was using an 8 foot step ladder which did not extend past the top of the unprotected excavation exposing him to a potential fall hazard, on or about 06/27/13.  Abatement Certification Required
Recent events (1)
  • — Z (S) $2400

1926.1053 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:   a) West Side of the Building - A laborer was using an 8 foot step ladder which was leaning against the side of the unprotected excavation exposing him to a potential fall hazard, on or about 06/27/13.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1926.1053 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:   a) West Side of the Building in the Alley - A laborer was stepping onto the top rung of an 8 foot step ladder which was leaning against the side of the unprotected excavation, in order to check the water flow from a manhole, exposing him to a potential fall hazard, on or about 06/27/13.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

MACY'S