DENVER, CO —
OSHA Inspection: B DIAZ CONSTRUCTION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of B DIAZ CONSTRUCTION INC. in 2703 KENTON STREET, DENVER, CO 80238 (NAICS 238130). OSHA activity number 339155889.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- B DIAZ CONSTRUCTION INC.
- Site address
- 2703 KENTON STREET
- City
- DENVER
- State
- CO
- ZIP
- 80238
- Mailing
- 6770 W. 44TH PLACE, WHEAT RIDGE, CO 80033
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.452 J03
- Issued
- Jul 30, 2013
- Abate by
- Aug 23, 2013
- Penalty
- Initial $1,496 · Current $900 Reduced
General-duty citation text
29 CFR 1926.452(j)(3): A workbench was used as a top guardrail even though it did not meet all of the guardrail requirements specified in 1926.451(g): a) B Diaz Construction Inc. at 2703 Kenton Street, Denver CO 80238: On or about June 29, 2013, a work bench used as a top guardrail was 31 inches above the working platform. This work bench was not installed between 38 inches and 45 inches high as required in 1926.451(g). Condition exposed employees to fall hazards of 15.6 feet. Abatement note: Standard guardrail requirements include a top rail set between 38 and 45 inches high, and a mid-rail set half way between the working platform and the top rail. End rails are also required.
Recent events (2)
- — I (S) $900
- — Z (S) $1496
1926.404 F06
- Issued
- Jul 30, 2013
- Abate by
- Aug 23, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) B Diaz Construction Inc. at 2703 Kenton Street, Denver CO 80238: On or about June 29, 2013, the employer did not ensure that a white extension cord was grounded. This extension cord was used to power a 120 volt Dura Air air compressor, and a 120 volt Ridgid circular saw, model Mg, serial number BB0547 65828. These tools were on a ground fault circuit interrupter (GFCI). Condition exposed employees to electrical shock hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at B Diaz Construction INC.
View B Diaz Construction INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339155889.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.