MARIETTA, GA —
OSHA Inspection: ADOLFO GARCIA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ADOLFO GARCIA in 1949 GRANITE MILL RD. LOT 19, MARIETTA, GA 30066 (NAICS 238170). OSHA activity number 339157976.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADOLFO GARCIA
- Site address
- 1949 GRANITE MILL RD. LOT 19
- City
- MARIETTA
- State
- GA
- ZIP
- 30066
- Mailing
- 2949 N. DEKALB DR. APT 272, DORAVILLE, GA 30340
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B05 II
- Issued
- Dec 23, 2013
- Abate by
- Dec 30, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(b)(5)(ii): Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end. a) Granite Mill Rd. Lot 19, Marietta GA. North side of building: An employee was exposed to falls of 12 feet while working from a pump jack scaffold that had platforms extending over its support 12 feet on the Northwest side and 5 feet on the Northeast side.
Recent events (1)
- — Z (S) $2800
1926.451 C02
- Issued
- Dec 23, 2013
- Abate by
- Dec 30, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. a) Granite Mill Rd. Lot 19, Marietta GA. North side of building: An employee was exposed to collapse hazards while working 12 feet above ground level from pump jack scaffolding that did not bare on base plates and mud sills or other adequate firm foundation.
Recent events (1)
- — Z (S) $2800
1926.452 J02
- Issued
- Dec 23, 2013
- Abate by
- Dec 30, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.452(j)(2): Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled. a) Granite Mill Rd. Lot 19, Marietta GA. North side of building: An employee was exposed to collapse hazards while working 12 feet above ground level from pump jack scaffolding that was not secured on the bottom.
Recent events (1)
- — Z (S) $2800
1926.452 J03
- Issued
- Dec 23, 2013
- Abate by
- Dec 30, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.452(j)(3): When guardrails are used for fall protection, a workbench may be used as the toprail only if it meets all the requirements in paragraphs (g)(4)(ii), (vii), (viii), and (xiii) of 1926.451. a) Granite Mill Rd. Lot 19, Marietta GA. North side of building: An employee was exposed to fall hazards while working 12 feet above ground level from pump jack scaffolding without mid or end rails
Recent events (1)
- — Z (S) $2800
1926.501 B13
- Issued
- Dec 23, 2013
- Abate by
- Dec 30, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. a) Granite Mill Rd. Lot 19, Marietta GA. North side of building: An employee was exposed to fall hazards of 10 ft to the ground below while exiting their pump jack scaffold on to a front porch roof to use an access ladder.
Recent events (1)
- — Z (S) $2800
More inspections at Adolfo Garcia
View Adolfo Garcia's full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339157976.