BRUNSWICK, GA ·
OSHA Inspection: AUTOMOTIVE PAINT & EQUIPMENT, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of AUTOMOTIVE PAINT & EQUIPMENT, LLC in 225 ROSE DRIVE, BRUNSWICK, GA 31520 (NAICS 444120). OSHA activity number 339160178.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AUTOMOTIVE PAINT & EQUIPMENT, LLC
- Site address
- 225 ROSE DRIVE
- City
- BRUNSWICK
- State
- GA
- ZIP
- 31520
- Mailing
- 225 ROSE DRIVE, BRUNSWICK, GA 31520
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 444120
- Employees
- 4
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 20, 2013
- Abate by
- Feb 10, 2014
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees a) Warehouse- On or about July 02, 2013, the employer allowed an employee to operate a Caterpillar propane forklift that did not have a seatbelt while transporting and moving paint products, exposing the employee to ejection, struck-by and crushing hazards. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
- · Z (S) $2000
1910.106 D05 I
- Issued
- Dec 20, 2013
- Penalty
- Initial $1,700 · Current $1,700
General-duty citation text
29 CFR 1910.106(d)(5)(i): "Egress." flammable liquids, including stock for sale, were stored in a location that limited the use of exits, stairways, or areas normally used for the safe egress of people. a) At the Warehouse, on or about and at times prior to July 02, 2013, the employer did not ensure that the exit door was free from all obstructions including stored flammable paint products, exposing employees to a fire hazard. CORRECTED DURING THE INSPECTION.
Recent events (1)
- · Z (S) $1700
1910.157 C01
- Issued
- Dec 20, 2013
- Abate by
- Jan 17, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) At the Paint Mixing Room, on or about and at times prior to July 02, 2013, a fire extinguisher was not mounted on the wall and was on the floor in the area designated by the employer to store paints, exposing employees to a fire hazard. The fire extinguisher was next to the metal shelves used to store the paint products and next to the rooms door. b) At the Warehouse, on or about and at times prior to July 02, 2013, a fire extinguisher was not mounted and was on the wall beam next to the exit door, exposing employees to a fire hazard. The fire extinguisher was located in the area designated to store the paint products inside the warehouse and next to the exit door leading outdoors. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
- · Z (S) $1600
1910.305 G01 IV A
- Issued
- Dec 20, 2013
- Abate by
- Feb 10, 2014
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) At the Paint Mixing Room, on or about and at times prior to July 02, 2013, an extension cord was used to power a paint shaker in lieu of using fixed wiring of a structure, resulting in an electrical hazard. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
- · Z (S) $1200
1910.134 C01
- Issued
- Dec 20, 2013
- Abate by
- Feb 10, 2014
- Penalty
- Initial $0 · Current $0
04602590
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) At the facility, on or about and at times prior to July 02, 2013, the employer did not implement a written Respiratory Protection Program for employees that were required to wear half mask respirators during paint mixing operations, exposing employees to respiratory irritation and dermatitis. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
- · Z (O) $0
More inspections in this industry (NAICS 444120)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339160178.