CLEVELAND, OH —
OSHA Inspection: POMPILI PRECAST CONCRETE
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of POMPILI PRECAST CONCRETE in 12307 BROADWAY AVE., CLEVELAND, OH 44125 (NAICS 327390). OSHA activity number 339160541.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- POMPILI PRECAST CONCRETE
- Site address
- 12307 BROADWAY AVE.
- City
- CLEVELAND
- State
- OH
- ZIP
- 44125
- Mailing
- 12307 BROADWAY AVE., GARFIELD HEIGHTS, OH 44125
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327390
- Employees
- 6
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.157 G01
- Issued
- Oct 18, 2013
- Abate by
- Dec 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting: Although portable fire extinguishers were available for employee use, neither initial, nor annual retraining was provided. Note: Employer may exercise one of the following options. 1. Provide portable fire extinguishers as specified in 29 CFR1910.157(c)(1), meet the distribution requirements per 29 CFR1910.157(d) (75 feet to the nearest extinguisher for Class A fires and 50 feet to the nearest unit for Class B fires), and provide training and education for all employees in the use of such equipment and the hazards associated with incipient stage firefighting as required in 29 CFR 1910.157(g). The other sections of 29 CFR also apply. 2. Provide extinguishers as specified in 29 CFR 1910.157(c)(1),designate certain employees to be the only employees authorized to use such equipment and require all other employees to immediately evacuate upon the sounding of the fire alarm, establish this in writing in an emergency action plan as outlined in 29 CFR1910.38(a) and train/educate designated employees per 1910.157(g).Utilizing this option exempts the employer from distribution requirements of 29 CFR 1910.157(d). 3. Establish a written fire safety policy which requires the immediate and total evacuation of employees from the workplace upon the sounding of a fire alarm signal. This policy shall include an emergency action plan and a fire prevention plan as specified in 29CFR 1910.38(a) and (b). Utilizing this option exempts the employer from the requirements of 29 CFR 1910.157 to include the need for providing portable fire equipment unless a specific standard requires that a portable fire extinguisher be provided (such as those requirements in 29 CFR 1910.106/107 related to use/storage of flammable/combustible liquids). If extinguishers are provided, but not intended for employee use, 29 CFR 1910.157(e) and (f) are still applicable (inspection, maintenance, and testing of equipment).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Pompili Precast Concrete
View Pompili Precast Concrete's full OSHA safety record →
More inspections in this industry (NAICS 327390)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339160541.