Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: LIGHTNING BAY PNEU~DRAULICS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LIGHTNING BAY PNEU~DRAULICS in ACROSS THE STREET FROM 10369 HIGHWAY 301, TAMPA, FL 33637 (NAICS 236210). OSHA activity number 339160640.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lightning BAY Pneu~Draulics for free Get an email when a new federal OSHA severe-injury report for Lightning BAY Pneu~Draulics is published. One employer, no account, unsubscribe in one click.
Site address
ACROSS THE STREET FROM 10369 HIGHWAY 301
City
TAMPA
State
FL
ZIP
33637
Mailing
1235 S. 82ND ST., TAMPA, FL 33619
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.651 C02

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 16, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1926.651(c)(2):     A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:    (a) In the trench excavation - when installing a storm pipe an employee was exposed to a cave-in hazard in that, a safe means of egress was not provided in the trench which was 8' feet in depth, on or about June 5, 2013.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1926.651 J02

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 16, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.    (a) At the edge of the trench - an employee was installing a storm pipe where the trench measured 8-ft deep. A spoil pile was staged at the edge of the trench, posed a hazard, in that, the trench was not sloped for class "C" soil, exposing the employee to engulfment and struck-by hazards from soil falling or rolling into the trench, on or about June 5, 2013.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 16, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1926.652(a)(1):     Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). The employer had not complied with the provisions of 29 CFR 1926.652(b)(1)(i) in that the:    (a) In a trench measuring 50 feet long, 12.6 feet wide and 8 feet deep - During the installation of a storm pipe an employee was required to work in an unprotected excavation next to an active roadway in type "C" soil. A protective system (shoring, shielding or sloping) was not provided for the employee, observed on or about June 5, 2013.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339160640.