Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: VHT INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of VHT INC. in 807 IIANIWAI ST., HONOLULU, HI 96813 (NAICS 811121). OSHA activity number 339160913.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch VHT INC. for free Get an email when a new federal OSHA severe-injury report for VHT INC. is published. One employer, no account, unsubscribe in one click.
Establishment
VHT INC.
Site address
807 IIANIWAI ST.
City
HONOLULU
State
HI
ZIP
96813
Mailing
807 IIANIWAI ST., HONOLULU, HI 96813
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
19
Ownership type
Private (A)

4 citations on file for this inspection.

1910.106 D04 III

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 15, 2013
Abate by
Aug 29, 2013
Penalty
Initial $1,020 · Current $1,020
29 CFR 1910.106(d)(4)(iii): Wiring. Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids, shall be approved for general use.     Employees were exposed to fire and explosion hazards in that electrical wiring located in the paint storage room was not rated class 1 division 2 for hazardous locations.  Category 2 flammable paint and paint products were stored and mixed in the room.
Recent events (2)
  • · I (S) $1020
  • · Z (S) $1020

1910.303 G02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 15, 2013
Abate by
Aug 29, 2013
Penalty
Initial $1,020 · Current $0 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures:     Employees working in the paint shop were exposed to electrical shock hazards in that the dual light switch was missing one of the switches thereby exposing the wiring.
Recent events (2)
  • · I (S) $0
  • · Z (S) $1020

1910.134 E01

Other-than-serious 1 instance 11 exposed
Issued
Jul 15, 2013
Abate by
Aug 29, 2013
Penalty
Initial $1,020 · Current $0 Reduced
29 CFR 1910.134(e)(1): General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.     Employees were exposed to respiratory hazards in that they were not medically evaluated before using the 3M tight-fitting respirators.  Employees working in the paint and body shops wore respirators while performing sanding and grinding activities.
Recent events (2)
  • · I (O) $0
  • · Z (S) $1020

1910.134 F02

Other-than-serious 1 instance 11 exposed
Issued
Jul 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter.     Employees were exposed to inhalation hazards, including isocyanates, in that they were not fit tested before using the 3M tight-fitting respirators.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339160913.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.