ORLANDO, FL —
OSHA Inspection: HALLIDAY PRODUCTS, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of HALLIDAY PRODUCTS, INC. in 6401 EDGEWATER DRIVE, ORLANDO, FL 32810 (NAICS 331524). OSHA activity number 339161572.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HALLIDAY PRODUCTS, INC.
- Site address
- 6401 EDGEWATER DRIVE
- City
- ORLANDO
- State
- FL
- ZIP
- 32810
- Mailing
- 6401 EDGEWATER DRIVE, ORLANDO, FL 32810
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331524
- Employees
- 57
- Ownership type
- A
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 5, 2013
- Penalty
- Initial $2,975 · Current $1,785 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a. Building 6453 - employees were exposed to a crushing hazard in the event of forklift tip over or from the operator falling out of the forklift, in that, the use of seat belts was not enforced. In addition, seat belts were not re-installed on forklifts after removal during events such as, but not limited to, re-upholstery of seats. Violation observed on or about 7/16/13. Feasible and acceptable methods to correct this hazardous condition would be to enforce use of seat belt use and to install a seat belt in accordance to the following requirements for powered industrial trucks ASME B56.1-1993 - Safety Standard for Low and High Lift Trucks; or to follow the safety instruction set forth in accordance with the manufacturer operator's instruction manual.
Recent events (2)
- — I (S) $1785
- — Z (S) $2975
1910.252 B03
- Issued
- Aug 5, 2013
- Abate by
- Aug 29, 2013
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.252(b)(3): Employees exposed to the hazards created by welding, cutting, or brazing operations were not protected by personal protective equipment in accordance with the requirements of 29 CFR 1910.132: a. Building 6401 - stainless steel and aluminum welding department - an employee was exposed to skin burns and ultraviolet rays, in that, the use of personal protective clothing and equipment was not enforced. The employee's legs were unprotected during stainless steel welding while wearing shorts and working in a sitting position. In addition, the employee was not wearing a welding apron, welding jacket or welding sleeves. Violation observed on or about 7//16/13.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.132 D02
- Issued
- Aug 5, 2013
- Abate by
- Aug 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: a. Buildings 6401 and 6453 - The employer did not develop a written certification for the hazard assessment performed. Violation observed on or about 07/03/13.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 C02 I
- Issued
- Aug 5, 2013
- Abate by
- Aug 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a. Buildings 6401 and 6453 - employees wearing a 3M filtering face piece device voluntarily were not provided with information contained in Appendix D. Violation observed on or about 07/03/13.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1026 D02 I
- Issued
- Aug 5, 2013
- Abate by
- Aug 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1026(d)(2)(i): The employer using the scheduled monitoring option did not perform initial monitoring to determine the 8-hour time-weighted average exposure to chromium (VI) for each employee on the basis of a sufficient number of personal breathing zone air samples to accurately characterize full shift exposure on each shift, for each job classification, in each work area: a. Building 6401 - the employer did not perform initial monitoring to determine the 8-hour time weighted average exposure to hexavalent chromium (Cr VI) for employees conducting stainless steel welding activities. Violation observed on or about 07/03/13.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01
- Issued
- Aug 5, 2013
- Abate by
- Aug 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. Buildings 6401 and 6453 - The employer did not develop a written hazard communication program where employees are exposed to chemical hazards such as, but not limited to, welding fumes containing hexavalent chromium. Violation observed on or about 07/03/13.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H01
- Issued
- Aug 5, 2013
- Abate by
- Aug 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a. Buildings 6401 and 6453 - employees welding aluminum and stainless steel components were not provided training on the hazardous chemicals, such as but not limited to, welding fumes containing hexavalent chromium. Violation observed on or about 07/03/13.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Halliday Products, INC.