OSHA Inspection: NATIONAL MILITARY ARMAMENT LLC (NATMIL)

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of NATIONAL MILITARY ARMAMENT LLC (NATMIL) in 1208 KNESEK LANE, VAN BUREN, AR 72956 (NAICS 332992). OSHA activity number 339167348.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch National Military Armament LLC (Natmil) for free Get an email when a new federal OSHA severe-injury report for National Military Armament LLC (Natmil) is published. One employer, no account, unsubscribe in one click.
Site address
1208 KNESEK LANE
City
VAN BUREN
State
AR
ZIP
72956
Mailing
1208 KNESEK LANE, VAN BUREN, AR 72956
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332992
Employees
8
Ownership type
Private (A)

8 citations on file for this inspection.

1910.151 C

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 2, 2013
Abate by
Dec 17, 2013
Penalty
Initial $2,200 · Current $2,200
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:   On or about July 2, 2013, at the facility, the employer did not have an eye wash station for quick drenching or flushing of the eyes and body for employees handling corrosive chemicals and melting solid lead including but not limited to 15 % by weight, Molybdenum Disulfide OSHA TWA: 15 mg/m^3; 15 % Acetone OSHA TWA: 2,400 mg/m^3; and lead OSHA TWA: 0.050 mg/m^3. This condition exposed employees to dermal hazards while working with and around the chemical agents.   Instance a:  Employees were painting gun primer sleeves, which exposed employees to conjunctiva and dermal hazards while performing painting operations.   Instance b:  Employees were cutting and melting lead for ammunition projectiles, which exposed employees to dermal hazards associated with the accumulation of dust while performing the tasks.
Recent events (3)
  • · F (S) $2200
  • · C (S) $2200
  • · Z (S) $2200

1910.305 B01 II

Other-than-serious 1 instance 2 exposed
Issued
Dec 2, 2013
Abate by
Dec 10, 2013
Penalty
Initial $2,640 · Current $0 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    On or about July 2, 2013, at the shop, where the employer did not ensure unused openings on the Galvanized Steel Square Electrical Conduit / Outlet Junction Boxes were closed or covered. This created an electrical shock, burn and fire hazard.
Recent events (3)
  • · F (O) $0
  • · C (S) $2640
  • · Z (S) $2640

1910.1025 D02

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 2, 2013
Abate by
Dec 10, 2013
Penalty
Initial $3,080 · Current $2,640 Reduced
29 CFR 1910.1025(d)(2): An initial determination was not made to determine if any employee may be exposed to lead at or above the action level:     On or about July 2, 2013, and at times prior thereto, at the shop, the employer did not determine if any employees were exposed to lead while cutting lead to slide into ammunition casings and melting lead to hand pour into ammunition projectiles for testing. This condition exposed employees to inhalation ingestion hazards while working with and around lead.
Recent events (3)
  • · F (S) $2640
  • · C (S) $3080
  • · Z (S) $3080

1910.1025 F02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 2, 2013
Abate by
Dec 17, 2013
Penalty
Initial $1,320 · Current $0 Reduced
29 CFR 1910.1025(f)(2)(i): The employer did not implement a respiratory protection program in accordance with 29 CFR 1910.134(b) through (d) (except (d)(1)(iii)), and (f) through (m) for each employee required by 29 CFR 1910.1025 to use a respirator:       On or about July 2, 2013, and at times prior thereto, the employer did not establish and implement a written respiratory protection program for employees exposed during lead melting operations.
Recent events (3)
  • · F (S) $0
  • · C (S) $1320
  • · Z (S) $1320

1910.1025 L01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 2, 2013
Abate by
Dec 10, 2013
Penalty
Initial $1,320 · Current $0 Reduced
29 CFR 1910.1025(l)(1)(i): Employee(s) working in an area where there is potential exposure to airborne lead at any level were not informed of the content of Appendices A and B of 29 CFR 1910.1025:      On or about July 2, 2013, and at times prior thereto, the employer did not inform or train employees of the health hazards associated with lead exposures.
Recent events (3)
  • · F (S) $0
  • · C (S) $1320
  • · Z (S) $1320

1910.1200 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 2, 2013
Abate by
Dec 17, 2013
Penalty
Initial $1,320 · Current $1,320
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):     On or about April 9, 2013, at the job site, the employer did not develop, implement, and maintain a written hazard communication program for employees handling corrosive chemicals and melting solid lead.
Recent events (3)
  • · F (S) $1320
  • · C (S) $1320
  • · Z (S) $1320

1910.303 F02

Other-than-serious 1 instance 2 exposed
Issued
Dec 2, 2013
Abate by
Dec 10, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:   On or about July 2, 2013, and at times prior thereto, at the shop, the employer did not ensure two electrical cabinets were labeled to identify their purpose.
Recent events (3)
  • · F (O) $0
  • · C (O) $0
  • · Z (O) $0

1910.1025 H01

Other-than-serious 2 instances 2 exposed
Issued
Dec 2, 2013
Abate by
Dec 10, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead:   On or about July 2, 2013, at the shop, the employer did not ensure work table and floor surfaces at and around where employees were cutting, melting and pouring lead were free from accumulations of lead. This created a condition for employees to be exposed to inhalation ingestion hazards associated with airborne or accumulative lead dust on surfaces.
Recent events (3)
  • · F (O) $0
  • · C (O) $0
  • · Z (O) $0