LAREDO, TX ·
OSHA Inspection: J.J. FLORES ROOFING AND CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of J.J. FLORES ROOFING AND CONSTRUCTION in 2400 BOB BULLOCK LOOP, LAREDO, TX 78040 (NAICS 238160). OSHA activity number 339169401.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J.J. FLORES ROOFING AND CONSTRUCTION
- Site address
- 2400 BOB BULLOCK LOOP
- City
- LAREDO
- State
- TX
- ZIP
- 78040
- Mailing
- 2601 ASH STREET, LAREDO, TX 78043
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.501 B10
- Issued
- Jul 30, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels and 50-feet (15.25 m) wide or less, was not protected from falling by guardrail systems, safety nets. At this construction job site, employees were installing roofing membranes on canopies at heights greater than six feet. The employees were not protected against falls from a roof.
Recent events (1)
- · Z (S) $2000
1926.1053 B16
- Issued
- Jul 30, 2013
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: At this job site, a Werner, twenty-four foot portable ladder had the following defects: A. Cracked side rail. B. Missing brackets on the ladder.
Recent events (1)
- · Z (S) $1200
More inspections at J.J. Flores Roofing and Construction
View J.J. Flores Roofing and Construction's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339169401.