EXETER, PA —
OSHA Inspection: BRIDON AMERICAN CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BRIDON AMERICAN CORPORATION in 101 STEVENS LN, EXETER, PA 18643 (NAICS 332618). OSHA activity number 339170441.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BRIDON AMERICAN CORPORATION
- Site address
- 101 STEVENS LN
- City
- EXETER
- State
- PA
- ZIP
- 18643
- Mailing
- 280 NEW COMMERCE BOULEVARD, WILKES BARRE, PA 18706
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332618
- Employees
- 142
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 C01
- Issued
- Sep 6, 2013
- Abate by
- Oct 24, 2013
- Penalty
- Initial $3,300 · Current $2,475 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder: a) Mechanical Parts Storage Mezzanine: Employees were exposed to a fall of approximately 8 feet while accessing an unprotected landing above the die shop, on or about July 10, 2013. b) Mezzanine over Welding Area: Employees were exposed to a fall of approximately 11 feet while accessing an unprotected landing, on or about July 10, 2013. c) Motor Storage Mezzanine: Employees were exposed to a fall of approximately 11 feet while accessing an unprotected landing, on or about July 10, 2013. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2475
- — Z (S) $3300
1910.303 B02
- Issued
- Sep 6, 2013
- Abate by
- Oct 24, 2013
- Penalty
- Initial $3,300 · Current $2,475 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling: a) Die Shop: A relocatable power tap connected to an extension cord and used to power a fluorescent light fixture and various components of an MSC milling machine was not used in accordance with its approved purpose, on or about July 10, 2013. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2475
- — Z (S) $3300
1910.305 G01 IV A
- Issued
- Sep 6, 2013
- Abate by
- Oct 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure: a) Production Area: An extension cord powering various components on machine #40 including a lamp and a machine sensor was installed and used in place of permanent wiring exposing workers to an electric shock hazard, on or about July 9, 2013. b) Swager Area: An extension cord providing power for the length counter on Swager A was installed and used in place of permanent wiring exposing workers to an electric shock hazard, on or about July 9, 2013. c) Die Shop: An extension cord providing power to a relocateable power tap (power strip) was installed and used in place of permanent wiring exposing workers to an electric shock hazard, on or about July 10, 2013. d) Warehouse: An extension cord providing power to a fixed receptacle mounted on a pedestal adjacent to machine #14 was installed and used in place of permanent wiring exposing workers to an electric shock hazard, on or about July 10, 2013. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Sep 6, 2013
- Abate by
- Oct 24, 2013
- Penalty
- Initial $4,125 · Current $3,094 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, in-going nip points, rotating parts, flying chips and sparks: a) Production Area: The Mark III roller forming unit on machine #31 was not adequately guarded exposing the operator to an in-going nip point hazard, on or about July 10, 2013. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $3093.75
- — Z (S) $4125
1910.215 A04
- Issued
- Sep 6, 2013
- Abate by
- Sep 18, 2013
- Penalty
- Initial $2,475 · Current $1,856 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rests were not kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage: a) Die Shop: The work rest on a Delta bench grinder was adjusted so that the gap between the abrasive wheel and the work rest was approximately 1 inch exposing workers to a struck-by hazard, on or about July 10, 2013. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1856.25
- — Z (S) $2475
1910.215 B09
- Issued
- Sep 6, 2013
- Abate by
- Sep 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top exceeded one-fourth inch: a) Die Shop: The tongue guard on a Delta bench grinder was adjusted to a distance of approximately 1/2 inch exposing workers to a struck-by hazard, on or about July 10, 2013. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Bridon American Corporation
View Bridon American Corporation's full OSHA safety record →
More inspections in this industry (NAICS 332618)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339170441.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.