Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MIDCON PRODUCTS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MIDCON PRODUCTS, INC. in 262 E. MAIN STREET, HORTONVILLE, WI 54944 (NAICS 327390). OSHA activity number 339170698.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Midcon Products, INC. — free Get an email when a new federal OSHA severe-injury report for Midcon Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
262 E. MAIN STREET
City
HORTONVILLE
State
WI
ZIP
54944
Mailing
P.O. BOX 370, HORTONVILLE, WI 54944
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
45
Ownership type
A

16 citations on file for this inspection.

1910.23 A02

Serious Gravity 5 3 instances 1 exposed
Issued
Jul 30, 2013
Abate by
Nov 4, 2013
Penalty
Initial $2,975 · Current $2,000 Reduced
29 CFR 1910.23(a)(2): Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person could not walk directly into the opening:    a)    The catwalk in the bin area had two openings for vertical ladders which had to be stepped across for platform access which were approximately 31 inches x 15 inches and 30 inches x 21 inches respectively.    b)    The elevator pit and pit access ladder opening was not guarded.  Only one chain was provided to protect access to the pit opening, and that chain sagged to 29 inches above the workfloor in the middle.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2975

1910.23 A08

Serious Gravity 1 3 instances 1 exposed
Issued
Jul 30, 2013
Abate by
Nov 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk was not guarded:    a)    The first landing in the bin area had an uncovered 4 inch x 4 inch hole in the grating.    b)    An unsecured wooden board  1-1/2 inches thick at the bin area was protecting a platform floor hole approximately 9 inches wide x 45 inches long.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.23 C02

Serious Gravity 5 3 instances 1 exposed
Issued
Jul 30, 2013
Abate by
Nov 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.23(c)(2): Runways four feet or more above floor or ground level were not guarded by standard railings (or the equivalent) and toeboards: Note:  Toeboards are only required where tools, machine parts, or materials are likely to be used on the runway:      a)    The catwalk in the bin area had open sides at the first platform, and on the catwalk where operators were exposed to a fall hazard.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.23 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 30, 2013
Abate by
Nov 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.23(d)(1): Flights of stairs having four or more risers were not equipped with a standard railing as specified in paragraphs (d)(1)(i) through (v) of this section:    a)    The stairs to the bin platform opening were approximately 60 inches high without any hand rails provided.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.24 B

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 30, 2013
Abate by
Nov 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.24(b): Fixed stairs were not provided for access from one structure level to another where operations necessitated regular travel between levels, and for access to operating platforms at any equipment which requires attention routinely during operations:    a)    No stairs were provided from the bin platform landing to the catwalk around the bins.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.25 D01 X

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 30, 2013
Abate by
Aug 7, 2013
Penalty
Initial $2,380 · Current $500 Reduced
29 CFR 1910.25(d)(1)(x): Portable wood ladder(s) were not inspected frequently and those which have developed defects shall be withdrawn from service for repair or destruction and tagged or marked as Dangerous, Do Not Use:    a)    The bottom half of extension being used as a straight ladder, approximately 15 inches in length in the elevator pit had two bad rungs at the ladder bottom, and the ladder had not been taken out of service.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $500
  • — Z (S) $2380

1910.151 C

Other-than-serious 1 instance 1 exposed
Issued
Jul 30, 2013
Abate by
Sep 4, 2013
Penalty
Initial $2,975 · Current $0 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    a)    Quick drenching facilities were not provided in the immediate vicinity of the Hydrochloric Acid tank to which an employee pours five gallon pails of caustic soda after climbing a 10 foot portable stairs.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (S) $2975

1910.178 Q07

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 30, 2013
Abate by
Aug 7, 2013
Penalty
Initial $2,975 · Current $1,000 Reduced
29 CFR 1910.178(q)(7): Industrial trucks were being placed in service after the examination showed condition(s) adversely affecting the safety of the vehicle:    a)    Lift truck operator put a Mitsubishi lift truck into service after discovering that an LP tank holdown bracket was missing.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2975

1910.180 D04

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 30, 2013
Abate by
Sep 4, 2013
Penalty
Initial $2,975 · Current $2,000 Reduced
29 CFR 1910.180(d)(4): Complete inspection(s) of crane(s) were not performed at intervals as generally defined in 1910.180(d)(ii) with a determination made as to whether deficiencies constituted a safety hazard:    a)    A complete crane inspection had not been conducted annually for the Grove 45 ton crane.  The inspection record listed an expiration date of 5/13 from the last annual inspection.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2975

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 30, 2013
Abate by
Nov 4, 2013
Penalty
Initial $2,975 · Current $2,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a)    Guards for the Voeller mixer were not being used while the mixer was in operation.    b)    A pinch point created by deck railings and overhead crane was not guarded.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2975

1910.303 B02

Serious Gravity 5 2 instances 2 exposed
Issued
Jul 30, 2013
Abate by
Sep 4, 2013
Penalty
Initial $2,975 · Current $2,000 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a)    Electrical tap being used outside in the movable building was not designed to be plugged into an extension cord.    b)    Temporary lights were not designed to be used as permanent lighting for movable building.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2975

1910.305 B02 I

Serious Gravity 5 3 instances 1 exposed
Issued
Jul 30, 2013
Abate by
Nov 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    a)    Junction boxes in the catwalk area of the bins for the weigh batcher did not have covers protecting contact with the wiring.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 30, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a)    The outer jacket on the sifter cord was badly damaged in two places.      ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A03 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 30, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(3)(i): A flexible cord used with the type of ground equipment did not contain an electrical equipment grounding conductor:  a)    An extension cord being used for the scale on the mixer platform did not contain a ground pin and was plugged into a live electrical outlet.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F05 I

Other-than-serious 1 instance 1 exposed
Issued
Jul 30, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:  a)    Spray bottle of Crete-Lease sitting on a shelf in the mixer control room did not have a label to identify the chemical or a hazard warning label for the chemical.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 F05 II

Other-than-serious 1 instance 1 exposed
Issued
Jul 30, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:  a)   Spray bottle of Crete-Lease sitting on a shelf in the mixer control room did not have a label to identify the chemical or a hazard warning label for the chemical.   ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Midcon Products, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339170698.