Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNITED FIREPROOFING, INC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of UNITED FIREPROOFING, INC in 810 BROAD STREET, NEWARK, NJ 07102 (NAICS 238310). OSHA activity number 339170839.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United Fireproofing, INC — free Get an email when a new federal OSHA severe-injury report for United Fireproofing, INC is published. One employer, no account, unsubscribe in one click.
Site address
810 BROAD STREET
City
NEWARK
State
NJ
ZIP
07102
Mailing
P.O BOX 400, LONG VALLEY, NJ 07853
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
10
Ownership type
A

2 citations on file for this inspection.

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 13, 2013
Abate by
Sep 30, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:   a)  810 Broad Street, 1st floor, Newark, NJ.  Employer did not provide his employee who is required to wear N95 series respirator with a medical evaluation.                                      Violation observed on or about 07/09/2013.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2000

1910.134 F01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 13, 2013
Abate by
Sep 30, 2013
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):     a)  810 Broad Street, 1st floor, Newark, NJ.    Employer did not provide employee who is required to wear 2200 N95 series respirator with a fit test.                                       Violation observed on or about 07/09/2013.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

View United Fireproofing, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339170839.