Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: ADCOCK CONCRETE, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of ADCOCK CONCRETE, INC. in BRIDGE ON INTERSTATE 70 NEAR WOLCOTT, CO, WOLCOTT, CO 81655 (NAICS 237310). OSHA activity number 339172611.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Adcock Concrete, INC. for free Get an email when a new federal OSHA severe-injury report for Adcock Concrete, INC. is published. One employer, no account, unsubscribe in one click.
Site address
BRIDGE ON INTERSTATE 70 NEAR WOLCOTT, CO
City
WOLCOTT
State
CO
ZIP
81655
Mailing
2458 INDUSTRIAL BLVD STE 1, GRAND JUNCTION, CO 81505
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237310
Employees
12
Ownership type
Private (A)

4 citations on file for this inspection.

1926.404 B01 II

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 26, 2013
Abate by
Dec 23, 2013
Penalty
Initial $1,785 · Current $893 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which were in use by employees did not have approved ground fault circuit interrupters for personal protection.  Receptacles on a :    a)  Adcock Concrete, Inc. at the Bridge on Interstate 70 near Wolcott, CO 81655:  On or before July 3, 2013, the employer did not ensure that the 120 volt 16 inch horizontal saw used to cut the bolts on the bridge curb was connected to a ground fault circuit interrupter (GFCI).  The employees plugged the saw to into extension cord, laid on the ground, and the extension cord was plugged into a Miller Bobcat 225 NT 8000 watt generator/welder, that did not provide a GFCI.  Condition exposed employees to electrical shock hazards.
Recent events (2)
  • · I (S) $892.5
  • · Z (S) $1785

1926.501 B01

Serious Gravity 10 10 instances 3 exposed
Issued
Nov 26, 2013
Abate by
Dec 23, 2013
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:     a)  Adcock Concrete, Inc. at the Bridge on Interstate 70 near Wolcott, CO 81655:  On or before July 3, 2013, the employer did not ensure employees were protected from falling when removing and replacing the guardrails and curbs on this bridge in the following instances:    1)  at the Wolcott Bridge, the employees used 6 foot shock absorbing lanyards for the bridge work with the jersey barriers set 12 feet back, and this design did not provide 100% fall protection as the employees carried tools and cut cement back and forth across the 150 foot long bridge; and    2)  at the Bridge at Mile Marker 154, the employees were not using used 100% fall protection when walking and working on this 1200 foot long bridge.      Conditions exposed these employees to fall hazards of up to 25 feet on the Wolcott Bridge, and more than 30 feet on the Bridge at Mile Marker 154.
Recent events (2)
  • · I (S) $2450
  • · Z (S) $4900

1926.502 D15

Serious Gravity 10 10 instances 3 exposed
Issued
Nov 26, 2013
Abate by
Dec 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(15): Anchorages used for attachment for personal fall arrest equipment were not capable of supporting at least 5,000 pounds per attached employee, nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person:  a)  Adcock Concrete, Inc. at the Bridge on Interstate 70 near Wolcott, CO 81655:  On or before July 3, 2013, the employer did not ensure that the personal fall arrest system anchorage points maintained a safety factor of at least two, and did not ensure the anchorages were installed by a qualified person in the following instances:    1)  at the Wolcott Bridge, the employees used 6 foot shock absorbing lanyards to connect to curb bolts, and there was no way to distinguish which bolts had been cut;  2)  at the Wolcott Bridge, the employees used 6 foot shock absorbing lanyards to connect to curb bolts, and the lanyards were not designed to connect to these bolts in that there was a risk of detachment;  3)  at the Wolcott Bridge, the employees used 6 foot shock absorbing lanyards to connect to curb bolts, and this process did not provide 100% fall protection for employees walking and working on this 150 foot long bridge;  4)  at the Wolcott Bridge, the employees used 6 foot shock absorbing lanyards to connect to chains, and the chains were wrapped in a loop, connected via chain hook to a chain link, and the chain hooks had no latches to prevent disengagement;  5)  at the Wolcott Bridge, the employees used 6 foot shock absorbing lanyards to connect to chains, and the lanyards were not designed to connect to the 5/16 inch and 3/8 inch chains, in that there was a risk of detachment;  6)  at the Wolcott Bridge, the employees used 6 foot shock absorbing lanyards to connect to chains, and the chains were wrapped in a loop around the jersey barrier connecting rods, but the chains were not secured to the rods to prevent the chains from jumping over the top of the rods;  7)  at the Wolcott Bridge, the employees used 6 foot shock absorbing lanyards to connect to a wire rope that was also used to support the 16 inch saw used to cut the curb, and the wire rope brackets were not secured at the ends; and  8)  at the Wolcott Bridge, the employees used 6 foot shock absorbing lanyards to connect to a wire rope used to support the 16 inch saw used to cut the curb, and the wire rope was not approved as a horizontal lifeline by a qualified person.   Conditions exposed these employees to fall hazards of up to 25 feet on the Wolcott Bridge, and more than 30 feet on the Bridge at Mile Marker 154.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.502 D16 III

Serious Gravity 10 10 instances 3 exposed
Issued
Nov 26, 2013
Abate by
Dec 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that employees could not free fall more than 6 feet nor contact any lower level:  a)  Adcock Concrete, Inc. at the Bridge on Interstate 70 near Wolcott, CO 81655:  On or before July 3, 2013, the employer did not ensure personal fall arrest systems were rigged to prevent a free fall of more than six feet in the following instance:  1)  at the Wolcott Bridge, the employees used 6 foot shock absorbing lanyards to connect to a wire rope set near the edge of the bridge, and which was used to support the 16 inch saw used to cut the curb, and this anchorage point did not prevent the employees from falling more than 6 feet;  2)  at the Bridge at Mile Marker 154, the employees used 6 foot shock absorbing lanyards to connect to a wire rope set near the edge of the bridge, and this anchorage point did not prevent the employees from falling more than 6 feet;  Conditions exposed these employees to fall hazards of up to 25 feet on the Wolcott Bridge, and more than 30 feet on the Bridge at Mile Marker 154.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Adcock Concrete, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339172611.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.