MONMOUTH JUNCTION, NJ —
OSHA Inspection: TRIS PHARMA, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TRIS PHARMA, INC. in 2031 ROUTE 130 SUITE D, MONMOUTH JUNCTION, NJ 08852 (NAICS 325412). OSHA activity number 339172678.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRIS PHARMA, INC.
- Site address
- 2031 ROUTE 130 SUITE D
- City
- MONMOUTH JUNCTION
- State
- NJ
- ZIP
- 08852
- Mailing
- 2031 ROUTE 130 SUITE D, MONMOUTH JUNCTION, NJ 08852
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325412
- Employees
- 275
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 II
- Issued
- Jan 8, 2014
- Abate by
- Feb 11, 2014
- Penalty
- Initial $2,550 · Current $1,530 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): Tris Pharma, Inc. Monmouth Junction, NJ site - Manufacturing Building: The Calibration and Preventative Maintenance (PM) of Process Vessels Standard Operatiing Procedure (SOP) did not include all the required elements of the Hazardous Energy Control (Lock Out/ Tag-Out) standard including: A) A specific statement of the intended use of the procedure; B) Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; C) Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and D) Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures. Condition noted on or about 7/22/2013.
Recent events (2)
- — I (S) $1530
- — Z (S) $2550
1910.178 A04
- Issued
- Jan 8, 2014
- Abate by
- Feb 11, 2014
- Penalty
- Initial $5,100 · Current $3,060 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications or additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: a) Tris Pharma, Inc. Monmouth Junction, NJ site - Manufacturing Building: Employer failed to obtain the written approval from the powered industrial truck's manufacturer (V. Mariotti) prior to employees using a fabricated steel cage platform on the forks to lift employees up during FLM cleaning operations. Condition noted on or about 7/10/2013.
Recent events (2)
- — I (S) $3060
- — Z (S) $5100
1910.178 A05
- Issued
- Jan 8, 2014
- Abate by
- Feb 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: a) Tris Pharma, Inc. Monmouth Junction, NJ site - Manufacturing Building: Employer failed to secure a load capacity plate on the (V. Mariotti) powered industrial truck which indicates the load capacity for the fabricated steel cage platform. Condition noted on or about 7/22/2013.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Tris Pharma, INC.
View Tris Pharma, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325412)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339172678.