Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,192,068Inspections Most recent open 2026-08-04 Last loaded 2026-08-07

OSHA Inspection: TONY DARCY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TONY DARCY in 273 BOSTON ROAD, BILLERICA, MA 01821 (NAICS 238160). OSHA activity number 339173072.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tony Darcy for free Get an email when a new federal OSHA severe-injury report for Tony Darcy is published. One employer, no account, unsubscribe in one click.
Establishment
TONY DARCY
Site address
273 BOSTON ROAD
City
BILLERICA
State
MA
ZIP
01821
Mailing
324 CONEY STREET, WALPOLE, MA 02081
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

6 citations on file for this inspection.

1926.300 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 27, 2013
Penalty
Initial $2,800 · Current $1,000 Reduced
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use.    (a) Location - Boston Road, Billerica, MA    On or about 7/29/13, an employee was exposed to struck by hazards while using an unguarded portable electric grinder.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2800

1926.404 B01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 27, 2013
Penalty
Initial $1,600 · Current $500 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.    (a) Location - Boston Road, Billerica MA    On or about 8/5/13, the employees were exposed to electrical shocks and burns when the employer failed to use GFCI while working with portable power tools.
Recent events (2)
  • · I (S) $500
  • · Z (S) $1600

1926.416 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 27, 2013
Penalty
Initial $2,800 · Current $1,000 Reduced
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:    (a) Location - Boston Road, Billerica, MA    On or about 8/5/13, the employees were exposed to electrical shock and burn hazards when working around an open conductor.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2800

1926.451 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 27, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation:    (a) Location - Boston Road, Billerica, MA:   On or about 7/10/13, the employer did not ensure that the scaffold was bearing on base plates or other adequate foundations.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1926.452 J02

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.452(j)(2): Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.  (a) Location - Boston Road, Billerica, MA: On or about 7/10/13, employees exposed to falls when the employer failed to ensure the pump jack scaffold poles were not secured at the bottom.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.501 B10

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 27, 2013
Penalty
Initial $2,800 · Current $1,000 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.    (a) Location - Boston Road, Billerica, MA:   On or about 7/10/13, employees were not protected from falling while working on a roof greater than six feet above a lower level.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2800

View Tony Darcy's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339173072.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.