Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WOMBLE COMPANY INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WOMBLE COMPANY INC. in 13605 INDUSTRIAL RD., HOUSTON, TX 77015 (NAICS 332812). OSHA activity number 339173387.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Womble Company INC. — free Get an email when a new federal OSHA severe-injury report for Womble Company INC. is published. One employer, no account, unsubscribe in one click.
Establishment
WOMBLE COMPANY INC.
Site address
13605 INDUSTRIAL RD.
City
HOUSTON
State
TX
ZIP
77015
Mailing
12821 INDUSTRIAL RD., HOUSTON, TX 77015
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
320
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 3 instances 6 exposed
Issued
Jul 25, 2013
Abate by
Aug 13, 2013
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:   The employer does not develop, document and utilize procedures for the control of potentially hazardous energy.   a. This violation occurred on or about July 9, 2013, in Plant 1 where employees were exposed to a struck-by and electrical shock hazard when servicing a conveyor system without written procedures for the control of potentially hazardous 220VAC and pneumatic energy.  b. This violation occurred on or about July 9, 2013, in Plant 2 where employees were exposed to a struck-by and electrical shock hazard when servicing a conveyor system without written procedures for the control of potentially hazardous 220VAC and pneumatic energy.  c. This violation occurred on or about July 9, 2013, in Plant 3 where employees were exposed to a struck-by and electrical shock hazard when servicing a conveyor system without written procedures for the control of potentially hazardous 220VAC and pneumatic energy.  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that procedures are developed, documented and utilized for the release of potentially hazardous energy.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5000

1910.253 B04 III

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 25, 2013
Abate by
Aug 13, 2013
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour:   The employer does not separate oxygen cylinders in storage from fuel-gas cylinders. This violation was observed on or about July 9, 2013, on the north exterior of Plant 2 where employees were exposed to a fire hazard when oxygen and acetylene compressed gas cylinders were stored without being separated. The cylinders were approximately 1 foot apart.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that oxygen cylinders in storage are separated from fuel-gas cylinders a minimum of 20 feet or by a noncombustible barrier at least 5 feet having a fire-resistance rating of at least one half hour.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5000

View Womble Company INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339173387.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.