OSHA Inspection: DAN MACHNIK DBA INTERSTATE ROOFING AND CONTRACTING SERVICES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DAN MACHNIK DBA INTERSTATE ROOFING AND CONTRACTING SERVICES in 1680 E. TOUHY AVE., DES PLAINES, IL 60016 (NAICS 238160). OSHA activity number 339175259.

Watch DAN Machnik DBA Interstate Roofing AND Contracting Services — free Get an email when a new federal OSHA severe-injury report for DAN Machnik DBA Interstate Roofing AND Contracting Services is published. One employer, no account, unsubscribe in one click.
Site address
1680 E. TOUHY AVE.
City
DES PLAINES
State
IL
ZIP
60016
Mailing
39475 N. ILLINOIS ROUTE 59, LAKE VILLA, IL 60046
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

10 citations on file for this inspection.

1926.252 A

Serious Gravity 5 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $2200.00 · Current $1540.00 Reduced
29 CFR 1926.252(a): An enclosed chute of wood, or equivalent material, was not used where materials were dropped more than 20 feet to points lying outside the exterior walls of the building(s):      a) Material and debris was thrown from the roof deck at an elevation of approximately 30 feet without the use of an enclosed chute.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — F (S) $1540
  • — C (S) $2200
  • — Z (S) $2200

1926.501 B01

Serious Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $3080.00 · Current $2140.00 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:           a) Employees were exposed to the hazard of falling approximately 30 feet while disposing of roofing materials and debris at the roof edge where fall protection had not been provided.         In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (S) $2140
  • — C (S) $3080
  • — Z (S) $3080

1926.501 B03

Serious Gravity 10 5 instances 1 exposed
Issued
Abate by
Penalty
Initial $3080.00 · Current $0.00 Reduced
29 CFR 1926.501(b)(3): Each employee in a hoist area was not protected from falling 6 feet (1.8m) or more to lower levels by guardrail systems or personal fall arrest systems:     a) Employees were exposed to the hazard of falling approximately 18 feet from the edge of a roof deck while manually hoisting materials at the edge of the roof deck.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (S) $0
  • — C (S) $3080
  • — Z (S) $3080

1926.501 B04 I

Serious Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $3080.00 · Current $0.00 Reduced
29 CFR 1926.501(b)(4)(i):  Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels by personal fall arrest systems, covers or guardrail systems erected around such holes:       a) Employees were exposed to the hazard of falling approximately 30 feet through unprotected skylights located in the roof deck work area.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (S) $0
  • — C (S) $3080
  • — Z (S) $3080

1926.501 B10

Serious Gravity 10 3 instances 7 exposed
Issued
Abate by
Penalty
Initial $3080.00 · Current $2140.00 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system:     a) Employees were exposed to the hazard of falling approximately 30 feet from roof deck edges while engaged in roofing activities without the use of fall protection or a safety monitoring system.       In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (S) $2140
  • — C (S) $3080
  • — Z (S) $3080

1926.502 J07 I

Serious Gravity 10 3 instances 7 exposed
Issued
Abate by
Penalty
Initial $3080.00 · Current $2140.00 Reduced
29 CFR 1926.502(j)(7)(i): Material and equipment were stored within 6 feet (1.8m) of a roof edge:       a) Materials and equipment were stored along the edge of the roof deck exposing employees to the hazard of falling approximately 30 feet.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (S) $2140
  • — C (S) $3080
  • — Z (S) $3080

1926.1053 A02

Serious Gravity 10 12 instances 7 exposed
Issued
Abate by
Penalty
Initial $3080.00 · Current $1540.00 Reduced
29 CFR 1926.1053(a)(2): Ladder rungs, cleats, and/or steps were not parallel, level, and uniformly spaced when the ladder was in position for use:     a) The steps of a portable ladder provided for employees to use while climbing on and over skylights on the roof deck were not uniformly spaced.       In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (S) $1540
  • — C (S) $3080
  • — Z (S) $3080

1926.1053 A03 I

Serious Gravity 10 12 instances 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(a)(3)(i): Rungs, cleats, and steps of portable ladders were spaced more than 14 inches (36 cm) apart, as measured along the ladder's side rails:     a) Several of the steps of a portable ladder provided for employees to use while climbing on and over skylights on the roof deck were spaced more than 14 inches apart.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.152 A01

Other-than-serious 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.152(a)(1): Containers other than approved metal safety cans or DOT approved containers were used for the handling and use of flammable liquids in quantities of 5 gallons or less:     a) A plastic gasoline container was provided for employee use to handle gasoline for the purpose of fueling roof cutting equipment.  The can was not an approved safety can because it did not have flash arrestor screens nor a self-closing lid.       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1926.503 B01

Other-than-serious 7 instances 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer:     a) The employer did not prepare written certification records related to employee fall protection training.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0