CHESAPEAKE, VA —
OSHA Inspection: COTTRELL CONTRACTING CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COTTRELL CONTRACTING CORP. in 328 N. BATTLEFIELD BLVD., CHESAPEAKE, VA 23320 (NAICS 336611). OSHA activity number 339177412.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COTTRELL CONTRACTING CORP.
- Site address
- 328 N. BATTLEFIELD BLVD.
- City
- CHESAPEAKE
- State
- VA
- ZIP
- 23320
- Mailing
- 328 N. BATTLEFIELD BLVD., CHESAPEAKE, VA 23320
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 8
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.253 E05 IV
- Issued
- Aug 6, 2013
- Abate by
- Sep 8, 2013
- Penalty
- Initial $2,380 · Current $1,785 Reduced
General-duty citation text
29 CFR 1910.253(e)(5)(iv): Hose connections shall be clamped or otherwise securely fastened in a manner that will withstand, without leakage, twice the pressure to which they are normally subjected in service, but in no case less than a pressure of 300 psi (2.04 MPa). Oil-free air or an oil-free inert gas shall be used for the test. a.) Cottrell Contracting: On or about 07/08/13, oxygen and fuel gas hoses were not pressure tested after repairs thereby exposed employees to a potential fire hazard.
Recent events (2)
- — I (S) $1785
- — Z (S) $2380
1910.304 B03 II A
- Issued
- Aug 6, 2013
- Penalty
- Initial $2,975 · Current $2,231 Reduced
General-duty citation text
29 CFR 1910.304(b)(3)(ii)(A): All 125-volt, single-phase, 15-, 20-, and 30-ampere receptacle outlets that are not part of the permanent wiring of the building or structure and that are in use by personnel shall have ground-fault circuit-interrupter protection for personnel. Note 1 to paragraph (b)(3)(ii)(A) of this section: A cord connector on an extension cord set is considered to be a receptacle outlet if the cord set is used for temporary electric power. Note 2 to paragraph (b)(3)(ii)(A) of this section: Cord sets and devices incorporating the required ground-fault circuit-interrupter that are connected to the receptacle closest to the source of power are acceptable forms of protection. a.) Cottrell Contracting: On or about 07/08/13, GFCI protection was not provided with a temporary switch box equipped with eight receptacle outlets use to supply power to extension cords, portable fan, portable grinder, vacuum cleaner and battery charger thereby exposed employees to a potential electrical shock.
Recent events (2)
- — I (S) $2231.25
- — Z (S) $2975
1910.304 G05
- Issued
- Aug 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective. a.) Cottrell Contracting; Rockbridge dredge: On or about 07/08/13, the path to ground of two 50' extension cords used to supply power to a portable fan and portable electrical tools were not permanent and continuous in that the ground prongs were missing from the male attachment plugs thereby exposed employees to a potential shock hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Aug 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws. a.) Cottrell Contracting Corporation; Storage building: On or about 07/08/13, strain relief was not provided for the conductor wires connected to the internal terminal of the temporary switch box used to supply power to receptacle outlets thereby exposed employees to a potential electrical shock.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1915.56 B02
- Issued
- Aug 6, 2013
- Penalty
- Initial $1,785 · Current $1,339 Reduced
General-duty citation text
29 CFR 1915.56(b)(2): Only cable free from repair or splices for a minimum distance of ten (10) feet from the cable end to which the electrode holder is connected shall be used, except that cables with standard insulated connectors or with splices whose insulating quality is equal to that of the cable are permitted. a.) Cottrell Contracting; Yard: On or about 07/08/13, black vinyl tape was applied over the outer insulation of a welding lead 5' below the electrode holder to cover uninsulated broken copper wires thereby exposed employee to a potential electrical shock.
Recent events (2)
- — I (S) $1338.75
- — Z (S) $1785
1915.73 D
- Issued
- Aug 6, 2013
- Penalty
- Initial $2,380 · Current $1,785 Reduced
General-duty citation text
29 CFR 1915.73(d): When employees are exposed to unguarded edges of decks, platforms, flats, and similar flat surfaces, more than 5 feet above a solid surface, the edges shall be guarded by adequate guardrails meeting the requirements of 1915.71(j)(1) and (2), unless the nature of the work in progress or the physical conditions prohibit the use or installation of such guardrails. a.) Cottrell Contracting; Rockbridge Dredge: On or about 07/08/13, a mid-rail was not provided along the edge of the main deck thereby exposed employees to a 10'10" fall to the ground.
Recent events (2)
- — I (S) $1785
- — Z (S) $2380
1910.134 E01
- Issued
- Aug 6, 2013
- Abate by
- Sep 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator. a.) Cottrell Contracting: On or about 07/08/13, a medical examination was not provided for employees required to wear a 3M half face tight fitting negative pressure air purifying respirator.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 F02
- Issued
- Aug 6, 2013
- Abate by
- Sep 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter. a.) Cottrell Contracting: On or about 07/08/13, a fit test was not provided for employees required to wear a 3M half face tight fitting negative pressure air purifying respirator.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L04 III
- Issued
- Aug 6, 2013
- Abate by
- Sep 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years. a.) Cottrell Contracting Corporation: On or about 07/08/13, employees required to operate a forklift truck were not provided with a performance evaluation every three years.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01 I B
- Issued
- Aug 6, 2013
- Abate by
- Sep 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(i)(B): The width of working space in front of the electric equipment shall be the width of the equipment or 762 mm (30 in.), whichever is greater. In all cases, the working space shall permit at least a 90-degree opening of equipment doors or hinged panels; a.) Cottrell Contracting Corporation; Storage building: On or about 07/08/13, the working space in front the main disconnect switch was not provided with a clearance of at least the 30".
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Cottrell Contracting Corp.