Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: KIEFFNER CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KIEFFNER CONSTRUCTION in 100 GROVE HILL DRIVE, OXFORD, MS 38655 (NAICS 238170). OSHA activity number 339178667.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kieffner Construction for free Get an email when a new federal OSHA severe-injury report for Kieffner Construction is published. One employer, no account, unsubscribe in one click.
Site address
100 GROVE HILL DRIVE
City
OXFORD
State
MS
ZIP
38655
Mailing
11845 BYHALIA ROAD, BYHALIA, MS 38611
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
7
Ownership type
Private (A)

2 citations on file for this inspection.

1926.451 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 23, 2013
Penalty
Initial $1,700 · Current $1,700
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.   Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part.   (a) T7 Townhouse - On or about July 11, 2013 employee was installing exterior trim using a pump jack scaffold without guardrail system or personal fall arrest system or safety net system on the end of the scaffold. The employee was exposed to a fall height of 25 feet.
Recent events (1)
  • · Z (S) $1700

1926.501 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 23, 2013
Penalty
Initial $1,700 · Current $1,700
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.   (a) T7 Townhouse - On or about July 11, 2013 employees were installing cement siding while standing on a 3/12 pitch roof without a guardrail system or personal fall arrest system or safety net system. The employees were exposed to a fall height of 11 feet.