Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: OBSERVA-DOME LABORATORIES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of OBSERVA-DOME LABORATORIES, INC. in 371 COMMERCE PARK DRIVE, JACKSON, MS 39213 (NAICS 332322). OSHA activity number 339189425.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Observa-Dome Laboratories, INC. for free Get an email when a new federal OSHA severe-injury report for Observa-Dome Laboratories, INC. is published. One employer, no account, unsubscribe in one click.
Site address
371 COMMERCE PARK DRIVE
City
JACKSON
State
MS
ZIP
39213
Mailing
371 COMMERCE PARK DRIVE, JACKSON, MS 39213
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
8
Ownership type
Private (A)

13 citations on file for this inspection.

1910.23 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 8, 2013
Penalty
Initial $1,040 · Current $624 Reduced
29 CFR 1910.23(e)(1): A standard railing shall consist of top rail, intermediate rail, and posts, and shall have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level. The top rail shall be smooth-surfaced throughout the length of the railing. The intermediate rail shall be approximately halfway between the top rail and the floor, platform, runway, or ramp. The ends of the rails shall not overhang the terminal posts except where such overhang does not constitute a projection hazard.  a) On or about July 15, 2013 the wooden stairway leading to the mezzanine in the paint shop was not equipped with a midrail.
Recent events (2)
  • · I (S) $624
  • · Z (S) $1040

1910.106 D03 I

Serious Gravity 5 1 instance 8 exposed
Issued
Aug 8, 2013
Abate by
Aug 20, 2013
Penalty
Initial $1,700 · Current $1,020 Reduced
29 CFR 1910.106(d)(3)(i): Maximum capacity. Not more than 60 gallons of Category 1, 2, or 3 flammable liquids, nor more than 120 gallons of Category 4 flammable liquids may be stored in a storage cabinet.  On or about July 15 2013 flammable chemicals such as Amerlock resin,  Amerlock cure, acetone, and gasoline was not stored in a flammable storage cabinet in the workplace where management and employees smoke.
Recent events (2)
  • · I (S) $1020
  • · Z (S) $1700

1910.134 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 8, 2013
Abate by
Sep 4, 2013
Penalty
Initial $1,836 · Current $1,102 Reduced
29 CFR 1910.134(c)(1): In any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer, the employer shall establish and implement a written respiratory protection program with worksite-specific procedures. The program shall be updated as necessary to reflect those changes in workplace conditions that affect respirator use. The employer shall include in the program the following provisions of this section, as applicable:  a) On or about July 15, 2013 employer has not implemented a respirator program where painters are requires to wear a 3M- half mask respirators.
Recent events (2)
  • · I (S) $1101.6
  • · Z (S) $1836

1910.134 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 8, 2013
Abate by
Sep 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.  a) On or about July 15, 2013 the employer had not provided medical evaluations to determine if employees wearing the 3M-half mask respirator were capable of wearing a respirator.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.134 F

Serious Gravity 5 3 instances 3 exposed
Issued
Aug 8, 2013
Abate by
Sep 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f): Fit testing. This paragraph requires that, before an employee may be required to use any respirator with a negative or positive pressure tight-fitting facepiece, the employee must be fit tested with the same make, model, style, and size of respirator that will be used. This paragraph specifies the kinds of fit tests allowed, the procedures for conducting them, and how the results of the fit tests must be used.   a) On or about July 15, 2013 employees wearing the 3M- half mask tight fitting facepiece respirator had not been fit tested.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.134 H02 I

Serious Gravity 1 3 instances 3 exposed
Issued
Aug 8, 2013
Abate by
Aug 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(2)(i): All respirators shall be stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals, and they shall be packed or stored to prevent deformation of the facepiece and exhalation valve.  a) On or about July 15, 2013 an employee respirator was not stored to protect from contaimination, dust, and deformation caused by extreme temperatures.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.253 B02 II

Serious Gravity 5 2 instances 7 exposed
Issued
Aug 8, 2013
Penalty
Initial $1,561 · Current $937 Reduced
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards.  On or about July 15, 2013 two Argon compressed tanks UN1006 were not secured by a chain or rack to prevent from falling.
Recent events (2)
  • · I (S) $936.6
  • · Z (S) $1561

1910.254 D08

Serious Gravity 5 2 instances 3 exposed
Issued
Aug 8, 2013
Penalty
Initial $1,301 · Current $781 Reduced
29 CFR 1910.254(d)(8): Electric shock. Cables with splices within 10 feet (3 m) of the holder shall not be used. The welder should not coil or loop welding electrode cable around parts of his body.  a) On or about July 15, 2013 the welding electrode cable had splices and exposed wiring within ten feet of the holder.
Recent events (2)
  • · I (S) $780.6
  • · Z (S) $1301

1910.305 B01 II

Serious Gravity 5 2 instances 8 exposed
Issued
Aug 8, 2013
Penalty
Initial $1,561 · Current $937 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed.  a) On or about July 15, 2013 an electrical panel box located at the southeast corner of the building had open spaces inside.  b) On or about July 15, 2013 the electrical panel box that controls the Gardner Denver compressor in the paint shop had open spaces inside.
Recent events (2)
  • · I (S) $936.6
  • · Z (S) $1561

1910.303 G01

Other-than-serious 2 instances 8 exposed
Issued
Aug 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.  a) On or about July 15, 2013 employer did not allow approximately three feet of clearence or to gain access to electrical panel boxes in the production area and paint shop that was blocked by a portable dust collection system, work table , microwave, and an ice machine.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 7 exposed
Issued
Aug 8, 2013
Abate by
Sep 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:  a) On or about July 15, 2013 employer had not implemented a written hazard communication program  for employees exposed to chemicals such as Amerlock resin, Amerlock cure and others.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1200 F06

Other-than-serious 1 instance 8 exposed
Issued
Aug 8, 2013
Abate by
Aug 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6): Workplace labeling. Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer shall ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked with either: The information specified under paragraphs (f)(1)(i) through (v) of this section for labels on shipped containers; or, Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.  On or about July 15, 2013 a seventy five gallon diesel storage tank was not label.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 8 exposed
Issued
Aug 8, 2013
Abate by
Sep 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and material safety data sheets.  a) On or about July 15, 2013 the employer had not provided hazard communication training for employees exposed to chemicals chemicals such as, but limited to, resin, paints, oxygen, acetylene, gasoline and diesel.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Observa-Dome Laboratories, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339189425.