Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: RENAN TORRES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RENAN TORRES in 3609 DIVISION ST, MANITOWOC, WI 54220 (NAICS 238160). OSHA activity number 339193633.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Renan Torres for free Get an email when a new federal OSHA severe-injury report for Renan Torres is published. One employer, no account, unsubscribe in one click.
Establishment
RENAN TORRES
Site address
3609 DIVISION ST
City
MANITOWOC
State
WI
ZIP
54220
Mailing
854 1/2 2ND ST., MENASHA, WI 54952
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
Private (A)

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 5 instances 5 exposed
Issued
Aug 6, 2013
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) On 7/15/13, employees of Renan Torres were performing roofing work without adequate or properly used Personal Fall Arrest Systems.  One employee had his lifeline tied to a rafter, three employees were not connected to lifelines, and two employees had not adjusted their harnesses correctly.
Recent events (1)
  • · Z (S) $1600

1926.503 A02

Serious Gravity 5 5 instances 5 exposed
Issued
Aug 6, 2013
Abate by
Sep 4, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii):  a) On and before 7/15/13, employees had not been trained to recognize fall hazards associated with roofing work or how to properly install and use personal fall arrest equipment.
Recent events (1)
  • · Z (S) $2000

View Renan Torres's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339193633.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.