Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SHERMAN MECHANICAL, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SHERMAN MECHANICAL, INC. in 333 ALICE ST., WHEELING, IL 60090 (NAICS 238220). OSHA activity number 339203424.

Watch Sherman Mechanical, INC. — free Get an email when a new federal OSHA severe-injury report for Sherman Mechanical, INC. is published. One employer, no account, unsubscribe in one click.
Site address
333 ALICE ST.
City
WHEELING
State
IL
ZIP
60090
Mailing
1075 ALEXANDER CT., CARY, IL 60013
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
2
Ownership type
A

4 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 31, 2013
Abate by
Aug 6, 2013
Penalty
Initial $6,300 · Current $3,150 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:     a) Employees were exposed to the hazard of falling approximately 22' from the upper roof of an industrial building to the ground during the performance of mechanical and related work activities.     b) Employees were exposed to the hazard of falling approximately 7'6" from the upper roof of an industrial building to a lower roof during the performance of mechanical and related work activities.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $3150
  • — Z (S) $6300

1926.501 B03

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 31, 2013
Abate by
Aug 6, 2013
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1926.501(b)(3):  Each employee in a hoist area was not protected from falling 6 feet (1.8 m) or more to lower levels by guardrail systems or personal fall arrest systems:       a) Employees were exposed to the hazard of falling approximately 14 feet to the ground while hoisting materials and working in a hoist area at the edge of a roof deck.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6300

1926.501 B04 I

Serious Gravity 10 12 instances 2 exposed
Issued
Jul 31, 2013
Abate by
Aug 6, 2013
Penalty
Initial $6,300 · Current $3,150 Reduced
29 CFR 1926.501(b)(4)(i):  Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels by personal fall arrest systems, covers or guardrail systems erected around such holes:     a) Employees were exposed to the hazard of falling approximately 22 feet through unprotected skylights located throughout to roof deck work area.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $3150
  • — Z (S) $6300

1926.1053 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 31, 2013
Abate by
Aug 6, 2013
Penalty
Initial $5,400 · Current $2,700 Reduced
29 CFR 1926.1053(b)(4):  Ladder(s) were used for purposes other than the purpose for which they were designed:     a) Employees were exposed to the hazard of falling approximately 7'6" while climbing on a stepladder without its metal spreaders or locking devices in the open position.   b) Employees were exposed to the hazard of falling approximately 7'6" while using a stepladder for access and egress between two points; a lower roof deck, and an upper roof deck.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $2700
  • — Z (S) $5400

View Sherman Mechanical, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339203424.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.