Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: ENERGY ONE AMERICA, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ENERGY ONE AMERICA, LLC in 1661 MORRIS ST. BUILDING KK AND KJ NAVAL STATION NORFOLK, NAVAL BASE, VA 23511 (NAICS 238390). OSHA activity number 339203853.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Energy ONE America, LLC for free Get an email when a new federal OSHA severe-injury report for Energy ONE America, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1661 MORRIS ST. BUILDING KK AND KJ NAVAL STATION NORFOLK
City
NAVAL BASE
State
VA
ZIP
23511
Mailing
454 JESSEN LANE, CHARLESTON, SC 29492
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238390
Employees
2
Ownership type
A

3 citations on file for this inspection.

1910.134 D01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 28, 2013
Abate by
Nov 15, 2013
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1910.134(d)(1)(i) as referenced by 29 CFR 1926.103: The employer shall select and provide an appropriate respirator based on the respiratory hazard(s) to which the worker is exposed and workplace and user factors that affect respirator performance and reliability.  a.)  Energy One America, Naval Station Norfolk, Building KK, Crawl Space:  On or about 07/24/13, an employee spraying foam insulation was over exposed to methylene bisphenyl isocyanate (MDI).  The employee was wearing an improper respirator in that the filter was not suitable for exposures to MDI, creating an exposure to toxic substance hazard.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $2800

1926.55 A

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 28, 2013
Abate by
Nov 15, 2013
Penalty
Initial $2,800 · Current $2,100 Reduced

Hazardous substances 1073

29 CFR 1926.55(a): Exposure of employees to inhalation, ingestion, skin absorption, or contact with any material or substance at a concentration above those specified in the "Threshold Limit Values of Airborne Contaminants for 1970" of the American Conference of Governmental Industrial Hygienists, shall be avoided. See Appendix A to this section.  a.)  Energy One America, Naval Station Norfolk, Building KK, Crawl Space:  On or about 07/24/13, an employee spraying foam insulation was exposed to methylene bisphenyl isocyanate (MDI) at a 15 minute Ceiling Level of 0.49 milligrams per cubic meter of air.  This is 2.45 times greater than the Ceiling Level of 0.20 milligrams per cubic meter of air.  Sampling was conducted on 07/24/13 for 15 minutes.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $2800

1926.55 B

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 28, 2013
Abate by
Nov 15, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 1073

29 CFR 1926.55(b): To achieve compliance with paragraph (a) of this section, administrative or engineering controls must first be implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and technical measures used for this purpose must first be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1926.103.  a.)  Energy One America, Naval Station Norfolk, Building KK, Crawlspace:  Engineering and work practice controls were not implemented to reduce employee exposures to methylene bisphenyl isocyanate (MDI) to levels below the Ceiling level of 0.20 milligrams per cubic meter of air.  The results of air sampling conducted on 07/24/13 indicated that employees performing spray foam insulation operations were exposed to MDI at a ceiling level of 0.49 milligrams per cubic meter of air.   ABATEMENT NOTE: Feasible engineering and work practice controls may include the following: 1.)  Local exhaust ventilation. 2.)  Use of a longer spray gun. 3.)  Train employees in work practices to reduce exposure.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Energy ONE America, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339203853.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.