Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: G&A BUILDING INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of G&A BUILDING INC. in 10281 N. BLUEBIRD LN, PARKER, CO 80134 (NAICS 238160). OSHA activity number 339205254.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G&A Building INC. for free Get an email when a new federal OSHA severe-injury report for G&A Building INC. is published. One employer, no account, unsubscribe in one click.
Establishment
G&A BUILDING INC.
Site address
10281 N. BLUEBIRD LN
City
PARKER
State
CO
ZIP
80134
Mailing
8400 E. YALE AVENUE #7-104, DENVER, CO 80231
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
Private (A)

1 citation on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 5 exposed
Issued
Jul 26, 2013
Abate by
Aug 14, 2013
Penalty
Initial $1,800 · Current $1,800
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system, or an alternative fall protection measure that meets a provision described in paragraph (b) of 29 CFR 1926.501:   a) On or about July 17th 2013, employees of G&A Building Inc. were exposed to fall hazards in excess of 6 feet while engaged in roofing activities on the roof of a residential building with no fall protection in place.      Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $1800
  • · Z (S) $1800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339205254.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.