OSHA Inspection: TUCKER DOUBLE DRIVE-IN, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of TUCKER DOUBLE DRIVE-IN, LLC in 4270 LAVISTA ROAD, TUCKER, GA 30084 (NAICS 722211). OSHA activity number 339213027.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tucker Double Drive-In, LLC for free Get an email when a new federal OSHA severe-injury report for Tucker Double Drive-In, LLC is published. One employer, no account, unsubscribe in one click.
Site address
4270 LAVISTA ROAD
City
TUCKER
State
GA
ZIP
30084
Mailing
4270 LAVISTA RD, TUCKER, GA 30084
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722211
Employees
15
Ownership type
A

6 citations on file for this inspection.

1910.22 A02

Serious Gravity 5 1 instance 24 exposed
Issued
Oct 24, 2013
Abate by
Nov 5, 2013
Penalty
Initial $1,800 · Current $1,040 Reduced
29 CFR 1910.22(a)(2): The floor of every workroom was not maintained in a clean and, so far as possible, a dry condition.   a.  On or about July 18, 2013 the employer did not ensure that the walking and working surface on the west side of the grill and food prep station was maintained in, so far as possible, a dry condition where there was water on the floor and an ongoing leak from the ceiling above.
Recent events (2)
  • · I (S) $1040
  • · Z (S) $1800

1910.23 A08

Serious Gravity 5 3 instances 24 exposed
Issued
Oct 24, 2013
Abate by
Nov 5, 2013
Penalty
Initial $1,800 · Current $1,040 Reduced
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk was not guarded:   a.  On or about July 18, 2013 a floor drain opening measuring 4-7/8 inches in diameter located adjacent to the entrances for the walk-in cooler and freezer units was not effectively guarded.  b.  On or about July 18, 2013 a floor drain opening measuring 4-7/8 inches in diameter at the north end of the grill and food preparation station was not effectively guarded.  c.  On or about July 18, 2013 a floor drain opening measuring 4-7/8 inches in diameter located on the east side of the food preparation station was not effectively guarded.
Recent events (2)
  • · I (S) $1040
  • · Z (S) $1800

1910.303 C03 I

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 24, 2013
Abate by
Nov 5, 2013
Penalty
Initial $1,800 · Current $1,120 Reduced
29 CFR 1910.303(c)(3)(i): Conductors were not spliced or joined with splicing devices identified for the use or by brazing, welding, or soldering with a fusible metal or alloy.    a. On or about July 18, 2013 two lengths of electrical conductor in the attic on the east side of the attic access were joined without a splicing device leaving exposed, energized conductors where an employee was required by the employer to access the roof in response to water leaking into the food preparation area.
Recent events (2)
  • · I (S) $1120
  • · Z (S) $1800

1910.303 G02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 24, 2013
Abate by
Nov 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact.   a.  On or about July 18, 2013 live parts of electrical equipment including neon sign transformers were not guarded in the attic access on the north end of the facility where an employee was required by the employer to access the roof in response to water leaking into the food preparation area.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 24, 2013
Abate by
Nov 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasion, and openings through which conductors enter were not effectively closed.   a.  On or about July 18, 2013 conductors entering a junction box were not protected from abrasion and the opening through which the conductors entered was not effectively closed above a high voltage transformer in the attic adjacent to the roof access where an employee was required by the employer to access the roof in response to water leaking into the food preparation area.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 B02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 24, 2013
Abate by
Nov 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose.   a.  On or about July 18, 2013 a junction box with improperly spliced electrical wiring for neon lights was not provided with a cover in the attic adjacent to the roof access where an employee was required by the employer to access the roof in response to water leaking into the food preparation area.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Tucker Double Drive-In, LLC's full OSHA safety record →