KERMIT, TX —
OSHA Inspection: BOPCO, LP
Federal Agency inspection · Health discipline
At a glance
On , OSHA opened a federal Agency health inspection of BOPCO, LP in KHY WATER STATION, SECTION 6, BLOCK B-3, KERMIT, TX 79745 (NAICS 213112). OSHA activity number 339219644.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOPCO, LP
- Site address
- KHY WATER STATION, SECTION 6, BLOCK B-3
- City
- KERMIT
- State
- TX
- ZIP
- 79745
- Mailing
- P.O. BOX 1019, KERMIT, TX 79745
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 26
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.1000 B02
- Issued
- Jan 15, 2014
- Abate by
- Jan 28, 2014
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.1000(b)(2): Employee(s) exposure to an airborne concentration of Hydrogen Sulfide listed in Table Z-2 in excess of the peak concentration of 50 PPM: The employer did not ensure an employee was not exposed to hydrogen sulfide above the maximum peak above the acceptable ceiling concentration of 50 ppm. On or about July 18th, 2013, an employee was exposed to hydrogen sulfide resullting in a blood thiosulfate level of 1.9 mcg/ml.
Recent events (1)
- — Z (S) $7000
1910.1000 E
- Issued
- Jan 15, 2014
- Abate by
- Jan 28, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a): On or about July 18, 2013, the employer did not implement feasible engineering and administrative controls to prevent employees from exposure to hydrogen sulfide (H2S). Feasible engineering and administrative controls include, but were not limited to: a) installation of a sight glass to prevent the need for opening the thief hatch, b) performance of air monitoring and use of a personal hydrogen sulfide meter, c) installation of a fixed hydrogen sulfide monitor at the tank d) positioning of the employee upwind of any contaminants contained within the headspace e) use of a blower to direct hydrogen sulfide away from the breathing zone of the employee, f) ventilate and direct contaminants to a flare or to a location remote from the employee's breathing zone.
Recent events (1)
- — Z (S) $0
1910.134 D01
- Issued
- Jan 15, 2014
- Abate by
- Jan 28, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(d)(1): The employer did not select and provide an appropriate respirator based on the respiratory hazard(s) to which the worker was exposed. On or about July 18, 2013, the employer did not provide in line air respirator to employees opening the hatch of a tank containing unknown quantities of chemicals exposing employees to inhalation hazards.
Recent events (1)
- — Z (S) $0
1910.134 H02 II A
- Issued
- Jan 15, 2014
- Abate by
- Jan 28, 2014
- Penalty
- Initial $6,300 · Current $6,300
General-duty citation text
29 CFR 1910.134(h)(2)(ii)(A): Emergency respirators were not kept accessible to the work area: On or about July 18, 2013, employees were exposed to Hydrogen Sulfide intoxication when emergency respirator was not provided and accessible at the work site.
Recent events (1)
- — Z (S) $6300
More inspections at Bopco, LP
View Bopco, LP's full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339219644.