OSHA Inspection: UNITED HARDWARE DISTRIBUTING COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of UNITED HARDWARE DISTRIBUTING COMPANY in 1102 WEST MILBANK AVENUE, MILBANK, SD 57252 (NAICS 444130). OSHA activity number 339220568.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United Hardware Distributing Company — free Get an email when a new federal OSHA severe-injury report for United Hardware Distributing Company is published. One employer, no account, unsubscribe in one click.
Site address
1102 WEST MILBANK AVENUE
City
MILBANK
State
SD
ZIP
57252
Mailing
1102 WEST MILBANK AVENUE, MILBANK, SD 57252
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444130
Employees
200
Ownership type
A

3 citations on file for this inspection.

1910.147 C02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 27, 2013
Abate by
Aug 30, 2013
Penalty
Initial $2,700 · Current $1,890 Reduced
29 CFR 1910.147(c)(2)(iii): Where major replacement, repair, renovation or modification of machine or equipment was performed, the employer did not provide an energy isolating device designed to accept a lockout device:   (a) On or about July 17, 2013, for employees exposed to potential electrical shock or electrocution hazards where maintenance was performed on the east overhead door motor and electrical control panel at 1102 West Milbank Avenue, Milbank, South Dakota.
Recent events (2)
  • — I (S) $1890
  • — Z (S) $2700

1910.147 C07 III

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 27, 2013
Abate by
Sep 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(iii): The employer did not provide retraining in energy control procedures for employees who underwent a change in their job assignments, a change in machines, equipment or processes that would present new hazard(s) or a change in the energy control procedures:  (a) On or about July 17, 2013, for employees exposed to potential electrical shock or electrocution hazards where maintenance was performed on the east overhead door motor and electrical control panel at 1102 West Milbank Avenue, Milbank, South Dakota.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Other-than-serious 1 instance 5 exposed
Issued
Aug 27, 2013
Abate by
Sep 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard were being followed:  (a) On or about July 17, 201,3 and at times prior to that date, for employees exposed to energy control hazards where maintenance is performed on machines, equipment and components at 1102 West Milbank Avenue, Milbank, South Dakota.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View United Hardware Distributing Company's full OSHA safety record →