Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BRASE CONSTRUCTION SERVICES, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of BRASE CONSTRUCTION SERVICES, INC. in 209 EAST MAIN STREET, COLLINSVILLE, IL 62234 (NAICS 238140). OSHA activity number 339221343.

Watch Brase Construction Services, INC. — free Get an email when a new federal OSHA severe-injury report for Brase Construction Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
209 EAST MAIN STREET
City
COLLINSVILLE
State
IL
ZIP
62234
Mailing
197 E HIGHWAY 40 SUITE B, TROY, IL 62294
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
1
Ownership type
A

2 citations on file for this inspection.

1926.404 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1300.00 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which were used by employees did not have approved ground fault circuit interrupters for personnel protection:       Employees using power tools connected to an extension cord with two cuts in the insulation were exposed to electrical shock and the employer did not ensure the temporary wiring was connected to ground fault circuit interrupters.
Recent events (2)
  • — I (S) $1300
  • — Z (S) $2400

1926.404 B01 III C

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(b)(1)(iii)(C): Where an assured equipment grounding conductor program was being utilized, the employer did not ensure that each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed  and not exposed to damage, was visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage:     Employees using power tools connected to an extension cord were exposed to electrical shock and the employer did not ensure the cord set was visually inspected before each days use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View BRASE CONSTRUCTION SERVICES, INC.'s full OSHA safety record →