BAYSIDE, NY ·
OSHA Inspection: ALL CITY STUCCO SYSTEM, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ALL CITY STUCCO SYSTEM, INC. in 219-20 NORTHERN BLVD., BAYSIDE, NY 11361 (NAICS 238140). OSHA activity number 339229338.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALL CITY STUCCO SYSTEM, INC.
- Site address
- 219-20 NORTHERN BLVD.
- City
- BAYSIDE
- State
- NY
- ZIP
- 11361
- Mailing
- 96-13 50 AVE., CORONA, NY 11368
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01
- Issued
- Sep 19, 2013
- Abate by
- Sep 25, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): (a) At the Worksite - A tubular welded scaffold two level high was not fully planked; on or about 07/19/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1926.451 E01
- Issued
- Sep 19, 2013
- Abate by
- Sep 25, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. (a) At the worksite - Employees used the scaffold frame to access the working surface; on or about 07/19/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1926.451 G01
- Issued
- Sep 19, 2013
- Abate by
- Sep 25, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: (a) At the worksite - A tubular welded scaffold with a working surface 13 feet 5 inches above a concrete sidewalk did not have guardrails; on or about 07/19/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1926.454 A
- Issued
- Sep 19, 2013
- Abate by
- Oct 1, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. (a) At the worksite - Employees were working from a tubular welded scaffold 13 feet 5 inches above a concrete sidewalk without fall protection, safe access and was not fully planked; on or about 07/19/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at ALL City Stucco System, INC.
View ALL City Stucco System, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339229338.