OSHA Inspection: ADVANCED BUILT STRUCTURES, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ADVANCED BUILT STRUCTURES, INC in 251 COLUMBIA ST, BROOKLYN, NY 11231 (NAICS 238120). OSHA activity number 339229957.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Advanced Built Structures, INC for free Get an email when a new federal OSHA severe-injury report for Advanced Built Structures, INC is published. One employer, no account, unsubscribe in one click.
Site address
251 COLUMBIA ST
City
BROOKLYN
State
NY
ZIP
11231
Mailing
150-C1 PACIFIC AVE, JERSEY CITY, NJ 07304
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
50
Ownership type
Private (A)

5 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 4 instances 2 exposed
Issued
Dec 2, 2013
Abate by
Dec 6, 2013
Penalty
Initial $4,620 · Current $2,310 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a program of frequent and regular inspections made by competent persons at the jobsite:      a)  Jobsite safety inspection was not provided to ensure that guardrails were installed as a complete guardrail system. Guardrails were not complete, missing midrails and toeboards in several locations.         Location:  251 Columbia St, Brooklyn N.Y.      On or about 7/18/2013      NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • · I (S) $2310
  • · Z (S) $4620

1926.501 C

Serious Gravity 5 4 instances 2 exposed
Issued
Dec 2, 2013
Abate by
Dec 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.501(c): The employer did not ensure that when employees were exposed to falling objects: In addition to having employees wear hardhats, the employer shall implement one of the measures outlined in 501(c)(1) through (c)(3) which include:  Provide a toeboard, or screen or the equivalent, or a canopy,  or keep objects back away from the edge,  or barricade the area to which objects can fall:    a) Toeboards or the equivalent were not provided on guardrails systems at the jobsite, at floor openings and roof edges.  Employees were exposed to being struck by falling objects during construction activities.     Location:  251 Columbia St, Brooklyn N.Y.    On or about 7/18/2013    NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.502 B02

Serious Gravity 5 3 instances 2 exposed
Issued
Dec 2, 2013
Abate by
Dec 9, 2013
Penalty
Initial $3,850 · Current $1,925 Reduced
29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were not installed between the top edge of the guardrail system and the walking surface:      a)  Midrails were not provided on guardrail systems surrounding floor openings at the top deck, at roof perimeter, and at window openings.  Employees were exposed to fall hazard during construction activities.        Location:  251 Columbia St, Brooklyn N.Y.      On or about 7/18/2013      NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • · I (S) $1925
  • · Z (S) $3850

1926.502 B09

Serious Gravity 5 4 instances 2 exposed
Issued
Dec 2, 2013
Abate by
Dec 6, 2013
Penalty
Initial $0 · Current $0
CFR 1926.502(b)(9):  The employer did not ensure that: If wire rope is used for top rails, it shall be flagged at not more than 6-foot (1.8m) intervals with high-visibility material:      a) The guardrail cables at the edge of the top deck were not provided with high visibility flagging.  Employees were exposed to fall hazard during construction activities.     Location:  251 Columbia St, Brooklyn N.Y.    On or about 7/18/2013    NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.502 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 2, 2013
Abate by
Dec 6, 2013
Penalty
Initial $0 · Current $0
CFR 1926.502(b)(13):  The employer did not ensure that:  When guardrails systems are used around holes which are used as points of access (such as ladderways), they shall be provided with a gate, or be so offset that a person cannot walk directly into the hole:      a)  The guardrail around the ladderway (floor opening) at the top deck was not provided with an offset guardrail.  Employees can fall 12 feet.    Location:  251 Columbia St, Brooklyn N.Y.    On or about 7/18/2013    NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Advanced Built Structures, INC's full OSHA safety record →