EAST POINT, GA —
OSHA Inspection: MARCOS CHAVEZ DELGADO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MARCOS CHAVEZ DELGADO in 3801 LAKE HAVEN WAY, EAST POINT, GA 30344 (NAICS 238140). OSHA activity number 339230146.
Where did this inspection happen?
- Establishment
- MARCOS CHAVEZ DELGADO
- Site address
- 3801 LAKE HAVEN WAY
- City
- EAST POINT
- State
- GA
- ZIP
- 30344
- Mailing
- 5643 ALDER DRIVE, FOREST PARK, GA 30297
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.102 A01
- Issued
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Employees shall be provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents. a) Front yard of 3801 Lake Haven Way, East Point. Georgia. The employer did not provide personal protective equipment, such as protective eye wear or a face shield, for the employees cutting stones to size with a 14-inch chop saw.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.300 B01
- Issued
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): When power operated tools are designed to accommodate guards, they shall be equipped with such guards when in use. a) Front yard of 3801 Lake Haven Way, East Point, Georgia. The employer did not ensure that the blade of a 14-inch chop saw, equipped with a diamond tipped blade, was properly guarded. The moveable self - retracting guard was missing from the chop saw.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.451 B01
- Issued
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): 29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, and the employer could not demonstrate that a wider space was necessary: a) Front of 3801 Lake Haven Way, East Point, Georgia. The upper most working platform of a fabricated frame supported scaffold was not completely planked or decked. Employees were exposed to a fall hazard of 11-feet 10-inches.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.451 G01
- Issued
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a) Front of 3801 Lake Haven Way, East Point, Georgia. Employees working from the upper working platform of the fabricated frame scaffold system were not protected from falling approximately 11-feet 10-inches to the ground by the use of guardrails, a safety net system or personal fall arrest systems.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.452 C02
- Issued
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frame scaffold(s) were not properly braced by crossbracing or diagonal braces, or both, to secure vertical members laterally and to align them so that the erected scaffold was plumb, square, and rigid: a) Front of 3801 Lake Haven Way, East Point, Georgia. The scaffold frames of the 11-foot 10-inch fabricated frame supported scaffold system were not adequately cross braced to ensure the scaffold frames were plumb, level, and square. The frames had only been braced on the outer frames, the interior of the frame were not braced at all. One of the frames was braced with what appeared to be a synthetic cargo tie down strap.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.451 C02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. a) Front of 3801 Lake Haven Way, East Point, Georgia. The legs 11-foot 10-inch high fabricated frame supported scaffolding system were not resting on an adequate foundation. The legs of the scaffold, which were not equipped with base plates, were resting directly on mud sills.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16 00:00:00
DC MASONRY
WINNETKA, IL—2026-07-15 00:00:00
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15 00:00:00
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14 00:00:00
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14 00:00:00
PLANET DESIGN SERVICES, INC.
More inspections in GA
GREENSBORO, GA—2026-07-16 00:00:00
PURE BEAUTY FARMS, INC.
FOREST PARK, GA—2026-07-16 00:00:00
POLYNT COMPOSITES USA INC.
AUGUSTA, GA—2026-07-16 00:00:00
GF CASTING SOLUTIONS AUGUSTA, LLC
CHAMBLEE, GA—2026-07-16 00:00:00
U.S. DEPARTMENT OF TREASURY
DECATUR, GA—2026-07-15 00:00:00
PALLETS ACQUISITION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339230146.