OSHA Inspection: DEE'S FOODSERVICE, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DEE'S FOODSERVICE, LLC in 19 BUTTERFIELD TRAIL, EL PASO, TX 79906 (NAICS 493120). OSHA activity number 339231516.

Watch Dee'S Foodservice, LLC — free Get an email when a new federal OSHA severe-injury report for Dee'S Foodservice, LLC is published. One employer, no account, unsubscribe in one click.
Site address
19 BUTTERFIELD TRAIL
City
EL PASO
State
TX
ZIP
79906
Mailing
19 BUTTERFIELD TRAIL, EL PASO, TX 79906
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493120
Employees
30
Ownership type
A

4 citations on file for this inspection.

1910.178 G02

Serious Gravity 5 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $1785.00 Reduced

Hazardous substances 23108870

29 CFR 1910.178(g)(2): Facilities were not provided for flushing and neutralizing spilled electrolyte, for fire protection, for protecting charging apparatus from damage by trucks, and for adequate ventilation for dispersal of fumes from gassing batteries.    WAREHOUSE AREA: On or about July 24, 2013 the employer did not ensure that the battery charging station was equipped with a guard/barrier to protect charging and related equipment from damage by trucks. This condition exposed employees to hazards associated with sulfuric acid and electrical shock.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2975

1910.178 P01

Serious Gravity 5 1 instance 30 exposed
Issued
Penalty
Initial $2023.00 · Current $1213.00 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):    WAREHOUSE AREA: On or about July 24, 2013 the employer did not ensure that a stand-up type forklift was operating with a functional back-up alarm system. This condition exposed employees to struck-by and caught-in-between hazards.
Recent events (2)
  • — I (S) $1213
  • — Z (S) $2023

1910.37 A04

Other-than-serious 1 instance 30 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:  WAREHOUSE AREA: On or about July 24, 2013 the employer did not ensure that the exit lighting was functional and/or located conspicuously at the exit door. This condition exposed employees to evacuation hazards in the event of a power outage or poor visibility during an emergency.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 J04 V

Other-than-serious 1 instance 30 exposed
Issued
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 8870

29 CFR 1910.305(j)(4)(v): The disconnect means was not readily accessible:   WAREHOUSE AREA: On or about July 24, 2013 the employer did not ensure that a disconnect electrical box was accessible in the event of an emergency. A warehouse mobile ladder and forklift(s) were impeding the path and/or access to the disconnect switch, exposing employees to electrical and/or other hazards associated with not having immediate access to the disconnect lever.