BROOKLYN, NY ·
OSHA Inspection: MACWAY CONCRETE
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MACWAY CONCRETE in 251 COLUMBIA ST, BROOKLYN, NY 11231 (NAICS 238110). OSHA activity number 339231813.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MACWAY CONCRETE
- Site address
- 251 COLUMBIA ST
- City
- BROOKLYN
- State
- NY
- ZIP
- 11231
- Mailing
- 6614 51ST ROAD, WOODSIDE NY 11377-7532, WOODSIDE, NY 11377
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 5
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.20 B02
- Issued
- Dec 2, 2013
- Abate by
- Dec 6, 2013
- Penalty
- Initial $1,600 · Current $3,400
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a program of frequent and regular inspections made by competent persons at the jobsite: a) The employer did not provide sufficient safety inspection before working on the 3fl concrete deck. The employer was operating a concrete trowel machine when the deck did not have a sufficient guardrail system and when employees of other trades were working below in the stairshaft. Location: 251 Columbia St, Brooklyn N.Y. On or about 7/18/2013 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (O) $3400
- · Z (S) $1600
1926.501 C
- Issued
- Dec 2, 2013
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(c): The employer did not ensure that when employees were exposed to falling objects: In addition to having employees wear hardhats, the employer shall implement one of the measures outlined in 501(c)(1) through (c)(3) which include: Provide a toeboard, or screen or the equivalent, or a canopy, or keep objects back away from the edge, or barricade the area to which objects can fall: a) Employees were exposed to being struck by falling equipment. The gas powered concrete trowel (helicopter trowel) was being operated at the edge of the 3fl concrete deck when employees were working below in the stair shaft. The guardrail around the stair shaft (floor opening) had a top rail but no midrail or toeboard and the machine fell off the edge. Location: 251 Columbia St, Brooklyn N.Y. On or about 7/18/2013 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $1600
1926.502 B09
- Issued
- Dec 2, 2013
- Abate by
- Dec 6, 2013
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
CFR 1926.502(b)(9): The employer did not ensure that: If wire rope is used for top rails, it shall be flagged at not more than 6-foot (1.8m) intervals with high-visibility material: a) The guardrail cables at the edge of the top concrete deck were not provided with high visibility flagging. Employees were exposed to fall hazard when operating the concrete trowel machine on the top deck. Location: 251 Columbia St, Brooklyn N.Y. On or about 7/18/2013 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $1600
1926.502 B13
- Issued
- Dec 2, 2013
- Abate by
- Dec 6, 2013
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
CFR 1926.502(b)(13): The employer did not ensure that: When guardrails systems are used around holes which are used as points of access (such as ladderways), they shall be provided with a gate, or be so offset that a person cannot walk directly into the hole: a) At the 3fl concrete deck: At the elevator shaft there was a gap in the guardrail where a ladder was placed. There was no gate or offset rail. Employees can fall 12 feet at the 15 inch wide gap. Location: 251 Columbia St, Brooklyn N.Y. On or about 7/18/2013 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.