COLORADO SPRINGS, CO ·
OSHA Inspection: PEP BOYS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PEP BOYS in 7625 N. ACADEMY BLVD., COLORADO SPRINGS, CO 80920 (NAICS 811111). OSHA activity number 339235301.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PEP BOYS
- Site address
- 7625 N. ACADEMY BLVD.
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80920
- Mailing
- 7625 N. ACADEMY BLVD., COLORADO SPRINGS, CO 80920
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 15000
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 7, 2013
- Abate by
- Aug 13, 2013
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing and struck-by hazards associated with improper automobile lift operations: a) On or about July 26, 2013 and at times prior to that date, employees were exposed to crushing and struck-by hazards while working around automotive lifts as follows: - Lifts were not inspected periodically by a qualified inspector. - Lifts were not inspected daily during use to ensure that they were properly maintained and functional. - Lifts were not locked and supported with vehicle stands while servicing vehicles. - Employees not using adapter pads while lifting vehicles on the lifts. - Employees were not properly trained on operating the vehicle lifts. - Lifts were not periodically maintained in accordance with the recommendation of the lift manufacturer. - Lifts were not provided with warning labels indicating their load limit and rated capacity. Abatement note: Feasible and acceptable methods to correct these hazardous conditions would be to follow the requirements in accordance to the instructions required in the ANSI/ALI ALOIM: 2008 Safety requirements for operation, inspection, and maintenance standard which includes but is not limited to the following: 1. Institute a periodic preventive maintenance program. 2. Lifts must be inspected by a qualified inspector. 3. Conduct and document periodic inspections and maintenance. 4. Retrain the employees' on the proper operating procedure for the vehicle lifts. 5. Provide the lifts with identification plates indicating their Model and Serial number. 6. Provide warning labels indicating their load limits and rated capacity.
Recent events (2)
- · I (S) $7000
- · Z (S) $7000
1910.253 B04 I
- Issued
- Aug 7, 2013
- Abate by
- Aug 13, 2013
- Penalty
- Initial $5,000 · Current $4,800 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease: a) On or about July 26, 2013 and at times prior, employees were exposed to explosion injuries from an oxygen cylinder stored together to an acetylene cylinder inside a compressor/oil room.
Recent events (2)
- · I (O) $4800
- · Z (S) $5000
1910.22 A01
- Issued
- Aug 7, 2013
- Abate by
- Aug 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition. a) On or about July 26, 2013 and at times prior, employees were exposed to fire hazards from several soiled rags that were left in the service bay area. The soiled rags were not put inside the designated red metal container can.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at PEP Boys
View PEP Boys's full OSHA safety record →
More inspections in this industry (NAICS 811111)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339235301.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.