OSHA Inspection: BAGIO'S CARPENTRY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BAGIO'S CARPENTRY in 2120 DUNMORE LN NW, WASHINGTON, DC 20010 (NAICS 238130). OSHA activity number 339237729.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bagio'S Carpentry for free Get an email when a new federal OSHA severe-injury report for Bagio'S Carpentry is published. One employer, no account, unsubscribe in one click.
Establishment
BAGIO'S CARPENTRY
Site address
2120 DUNMORE LN NW
City
WASHINGTON
State
DC
ZIP
20010
Mailing
16120 ASA DR, SPENCERVILLE, MD 20868
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
10
Ownership type
Private (A)

5 citations on file for this inspection.

1926.304 H01

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 10, 2013
Penalty
Initial $2,520 · Current $2,520
29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut:  a) On July 26, 2013 and at times prior thereto; front of building; employees were using a table saw that was not properly guarded.
Recent events (1)
  • · Z (S) $2520

1926.403 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 10, 2013
Abate by
Sep 28, 2013
Penalty
Initial $1,224 · Current $1,224
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees:   a) On July 26, 2013 and at times prior thereto; front of site, employees were operating a table saw which was not equipped with an anti-restart/magnetic switch to prevent it from accidental start up if the power was lost and re-engaged.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • · Z (S) $1224

1926.451 B01

Serious Gravity 10 2 instances 2 exposed
Issued
Sep 10, 2013
Penalty
Initial $2,520 · Current $2,520
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)   a) On July 26, 2013 and at times prior thereto; front of building, employees were observed on the working on the platform that was not fully planked, missing several planks; the height from the work platform to ground level was 22 feet.
Recent events (1)
  • · Z (S) $2520

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 10, 2013
Penalty
Initial $2,520 · Current $2,520
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:   a) July 26, 2013 and at times prior thereto; front of site, employees working on a scaffold system were not protected from falling 22 feet to ground level by falling by a personal arrest system
Recent events (1)
  • · Z (S) $2520

1926.1053 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 10, 2013
Penalty
Initial $2,520 · Current $2,520
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder.   a) On July 26, 2013 and at times prior thereto; front area, the ladder used to access the scaffold was not extended three feet above the platform exposing the employees to a fall hazard.
Recent events (1)
  • · Z (S) $2520

View Bagio'S Carpentry's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339237729.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.