HARTFORD, CT ·
OSHA Inspection: GREEN EARTH ENERGY PHOTO VOLTAIC, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GREEN EARTH ENERGY PHOTO VOLTAIC, LLC in 41 WALNUT STREET, HARTFORD, CT 06103 (NAICS 238220). OSHA activity number 339240814.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GREEN EARTH ENERGY PHOTO VOLTAIC, LLC
- Site address
- 41 WALNUT STREET
- City
- HARTFORD
- State
- CT
- ZIP
- 06103
- Mailing
- 208 SHAKER ROAD, LONGMEADOW, MA 01106
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B01
- Issued
- Sep 9, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. On or about 07/25/2013 and 07/31/2013 at the 41 Walnut Street Solar Panel Installation Project, employees were exposed to fall hazards while installing solar panels to a roof and were not using any fall protection system.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1926.502 D15
- Issued
- Sep 9, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage points used for attachment of personal fall arrest equipment were not independent of any anchorage point being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee: On or about 07/25/2013 at the 41 Walnut Street Solar Panel Installation Project, two employees were tied off to a single anchorage that was only designed to be used as a single anchorage for one person.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1926.1053 B01
- Issued
- Sep 9, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder�s length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On or about 07/25/2013 at the 41 Walnut Street Solar Panel Installation Project, employees were using an extension ladder to access and descend to and from the roof deck and the ladder did not extend at least 3 feet past the roof landing.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
More inspections in this industry (NAICS 238220)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339240814.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.