Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,192,068Inspections Most recent open 2026-08-04 Last loaded 2026-08-07

OSHA Inspection: GREEN EARTH ENERGY PHOTO VOLTAIC, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GREEN EARTH ENERGY PHOTO VOLTAIC, LLC in 41 WALNUT STREET, HARTFORD, CT 06103 (NAICS 238220). OSHA activity number 339240814.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Green Earth Energy Photo Voltaic, LLC for free Get an email when a new federal OSHA severe-injury report for Green Earth Energy Photo Voltaic, LLC is published. One employer, no account, unsubscribe in one click.
Site address
41 WALNUT STREET
City
HARTFORD
State
CT
ZIP
06103
Mailing
208 SHAKER ROAD, LONGMEADOW, MA 01106
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.501 B01

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 9, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  On or about 07/25/2013 and 07/31/2013 at the 41 Walnut Street Solar Panel Installation Project, employees were exposed to fall hazards while installing solar panels to a roof and were not using any fall protection system.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1926.502 D15

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 9, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.502(d)(15): Anchorage points used for attachment of personal fall arrest equipment were not  independent of any anchorage point being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee:  On or about 07/25/2013 at the 41 Walnut Street Solar Panel Installation Project, two employees were tied off to a single anchorage that was only designed to be used as a single anchorage for one person.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 9, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder�s length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  On or about 07/25/2013 at the 41 Walnut Street Solar Panel Installation Project, employees were using an extension ladder to access and descend to and from the roof deck and the ladder did not extend at least 3 feet past the roof landing.