SAVANNAH, GA —
OSHA Inspection: PACE ELECTRICAL CONTRACTORS, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of PACE ELECTRICAL CONTRACTORS, INC. in 202 WHEELER ST., SAVANNAH, GA 31405 (NAICS 238210). OSHA activity number 339243867.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PACE ELECTRICAL CONTRACTORS, INC.
- Site address
- 202 WHEELER ST.
- City
- SAVANNAH
- State
- GA
- ZIP
- 31405
- Mailing
- 131 SOUTHERN BLVD., SAVANNAH, GA 31405
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 20
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Sep 11, 2013
- Abate by
- Oct 7, 2013
- Penalty
- Initial $1,700 · Current $1,100 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about July 31, 2013 and at times prior to, employees were observed working on the roof of a residential building without fall protection such as, but not limited to conventional and or a safety monitor, exposing employees up to an 8 foot fall hazard. ABATEMENT CERTIFICATION AND DOCUMENTATION ARE REQUIRED.
Recent events (2)
- — I (S) $1100
- — Z (S) $1700
1926.1053 B01
- Issued
- Sep 11, 2013
- Penalty
- Initial $1,445 · Current $1,100 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. a) On or about June 3, 2013 and at times prior to, an extension ladder was used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet above the upper landing surface, exposing the employees to fall hazard of about 8 feet.
Recent events (2)
- — I (S) $1100
- — Z (S) $1445
More inspections at Pace Electrical Contractors, INC.
View Pace Electrical Contractors, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339243867.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.