Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JAY-BEE OIL AND GAS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JAY-BEE OIL AND GAS, INC. in 429 SIMONTON ROAD, ELLENBORO, WV 26346 (NAICS 213111). OSHA activity number 339244410.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jay-Bee OIL and GAS, INC. — free Get an email when a new federal OSHA severe-injury report for Jay-Bee OIL and GAS, INC. is published. One employer, no account, unsubscribe in one click.
Site address
429 SIMONTON ROAD
City
ELLENBORO
State
WV
ZIP
26346
Mailing
3570 SHIELDS HILL ROAD, CAIRO, WV 26337
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
55
Ownership type
A

5 citations on file for this inspection.

1910.106 D02 I

Other-than-serious 1 instance 3 exposed
Issued
Sep 27, 2013
Abate by
Oct 3, 2013
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1910.106(d)(2)(i): Approved container(s) or portable tank(s) were not used for the storage of flammable or combustible liquids:      (a) Inside the Shop: Employees stored oil in an open plastic container, as observed on 07/31/2013.
Recent events (2)
  • — I (O) $2100
  • — Z (S) $2800

1910.106 D02 III

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Sep 27, 2013
Abate by
Oct 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.106(d)(2)(iii): Flammable or combustible liquid containers were not in accordance with Table H12:     (a) Inside the Shop: Employees store a mixture of approximately four gallons of diesel, gasoline, and oil in an open plastic container to be used for cleaning parts. The container is not in accordance with Table H12 in that only 1 gallon of Category 3 flammables are permitted in plastic containers, as observed on or about 07/31/2013.      ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 C01

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 27, 2013
Abate by
Oct 3, 2013
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:    (a) Water/Brine Truck: Employees climb into 20 inch confined space opening to clean out the trucks and/or make repairs. The employer has not evaluated the workplace to determine if the space is permit required confined space as determined on or about 07/31/2013.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2100

1910.243 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 27, 2013
Abate by
Oct 3, 2013
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4):       (a) Inside the Shop: Employees use a Dewalt angle grinder to grind down welds and burrs during truck tank repairs. The grinder was not equipped with a guard, as observed on or about 07/31/2013.       ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1910.253 B02 II

Other-than-serious 1 instance 3 exposed
Issued
Sep 27, 2013
Abate by
Oct 3, 2013
Penalty
Initial $3,500 · Current $2,625 Reduced
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior:      (a) Inside the Shop; Next to Garage Bay Door: Acetylene cylinders were stored within 9 feet of oil storage tanks, as observed on 07/31/2013.
Recent events (2)
  • — I (O) $2625
  • — Z (S) $3500

View Jay-Bee OIL and GAS, INC.'s full OSHA safety record →