WAHIAWA, HI —
OSHA Inspection: KILANI FENDER, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of KILANI FENDER, INC. in 322 PALM ST., WAHIAWA, HI 96786 (NAICS 811121). OSHA activity number 339245037.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KILANI FENDER, INC.
- Site address
- 322 PALM ST.
- City
- WAHIAWA
- State
- HI
- ZIP
- 96786
- Mailing
- 322 PALM ST., WAHIAWA, HI 96786
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 10
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.134 C01
- Issued
- Aug 12, 2013
- Abate by
- Sep 14, 2013
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) Sanding and Painting Operations: On July 31, 2013 and at times prior thereto, a respiratory protection program had not been written or implement for employees who voluntarily wear tight fitting respirators and employees required to wear air-supplied respiratory hoods.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1910.134 C02 I
- Issued
- Aug 12, 2013
- Abate by
- Sep 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: (a) Sanding Operations: On July 31, 2013 and at times prior thereto, Appendix D was not provided to an employee who voluntarily wore tight fitting respirators including a North 7700 and a 3M half-face respirator while sanding vehicles.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 D01 I
- Issued
- Aug 12, 2013
- Abate by
- Sep 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(d)(1)(i): Selection of appropriate respirators was not based on the respiratory hazard(s) to which the worker was exposed and user factors that affect respirator performance and reliability: (a) Sanding Operations: On July 31, 2013 and at times prior thereto, a North 7700 half face respirator equipped with North N7500-3 cartridges was who worn while sanding vehicles which produces airborne particles. The N7500-3 cartridges are designed to provide protection for exposures to Organic Vapor, Chlorine, Hydrogen Chloride, Sulfur Dioxide, Hydrogen Fluoride and Chlorine Dioxide but not particles.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 E01
- Issued
- Aug 12, 2013
- Abate by
- Sep 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Sanding Operations: On July 31, 2013 and at times prior thereto, employees who voluntarily wore tight fitting respirators, including a North 7700 half face respirator and a 3M half-face respirator, while sanding vehicles were not medically evaluated prior to wearing the respirators. (b) Painting Operations: On July 31, 2013 and at times prior thereto, employees who were required to wear an air-supplied SATA 51854 respirator hood while painting in the spray booth were not medically evaluated prior to wearing the respirator.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 H02 I
- Issued
- Aug 12, 2013
- Abate by
- Sep 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: (a) Sanding Operations: On July 31, 2013, a North 7700 half face respirator was stored in an open tool caddy, exposing the respirator to dust and other contaminants present in the work area.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Aug 12, 2013
- Abate by
- Sep 6, 2013
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) Facility Wide: On July 31, 2013, a written Hazard Communications Program had not been developed or implemented. Hazardous chemicals at the site included, but were not limited to, auto body paints and hardeners containing isocyanates.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1910.1200 E01 I
- Issued
- Aug 12, 2013
- Abate by
- Sep 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present, using an identity that was referenced on the appropriate material safety data sheet: (a) Facility Wide: On July 31, 2013, a hazardous material inventory was not available.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 G08
- Issued
- Aug 12, 2013
- Abate by
- Sep 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not ensure that material safety data sheets were readily accessible to the employees in their work area during each work shift: (a) Facility Wide: On July 31, 2013, the employer was not able to readily locate and produce a Material Safety Data Sheet (MSDS) for the Sherwin Williams UH904 Ultrasystem Speed-Plus Performance Hardener, which contained isocyanates.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 D02
- Issued
- Aug 12, 2013
- Abate by
- Sep 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: (a) Facility Wide: On July 31, 2013, a certified personal protective equipment hazard assessment was not available.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Kilani Fender, INC.
View Kilani Fender, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 811121)
More inspections in HI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339245037.