KAILUA KONA, HI ·
OSHA Inspection: ADVANCED PC ENTERPRISES, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ADVANCED PC ENTERPRISES, INC. in 73-5677 LAWEHANA ST, STE 6, KAILUA KONA, HI 96740 (NAICS 325510). OSHA activity number 339245052.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCED PC ENTERPRISES, INC.
- Site address
- 73-5677 LAWEHANA ST, STE 6
- City
- KAILUA KONA
- State
- HI
- ZIP
- 96740
- Mailing
- 73-5677 LAWEHANA ST, STE 6, KAILUA KONA, HI 96740
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325510
- Employees
- 2
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.134 C01
- Issued
- Oct 18, 2013
- Abate by
- Nov 29, 2013
- Penalty
- Initial $1,200 · Current $750 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a. On or about July 23, 2013, the abrasive blaster was required to wear a supplied air respirator and a N95 dustmask respirator. The employer did not establish and implement a written respiratory protection program that addressed the worksite-specific procedures such as but not limited to employee medical evaluation, fit testing, training on the use, maintenance and care of the respirators.
Recent events (2)
- · I (S) $750
- · Z (S) $1200
1910.134 D01 II
- Issued
- Oct 18, 2013
- Abate by
- Nov 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(d)(1)(ii): The employer did not select and use a NIOSH-certified respirator in compliance with the conditions of its certification: a. On or about July 23, 2013, the employer used a non-NOVA 2000 air supply hose in the airline respirator assembly which voided the NIOSH approval of the entire assembly. OR IN THE ALTERNATIVE 29 CFR 1910.94(a)(5)(i): On or about July 23, 2013, the employer used a non-NOVA 2000 air supply hose in the NOVA 2000 airline respirator assembly which voided the NIOSH approval of the entire assembly
Recent events (1)
- · Z (S) $0
1910.134 E01
- Issued
- Oct 18, 2013
- Abate by
- Nov 29, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a. On or about July 23, 2013, an employee who wore a NOVA 2000 Helmet and N95 dustmask respirator had not been provided with a medical evaluation prior to wearing the respirators.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 F01
- Issued
- Oct 18, 2013
- Abate by
- Nov 29, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a. On or about July 23, 2013, an employee who was required to wear a NIOSH approved N95 dustmask respirator had not been fit tested prior to initial use of the respirator.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 I07
- Issued
- Oct 18, 2013
- Abate by
- Nov 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both: a. On or about July 23, 2013, the oil-lubricated air compressor used to provide compressed breathing air was not equipped with a carbon monoxide alarm or high temperature alarm.
Recent events (1)
- · Z (S) $0
1910.134 K03
- Issued
- Oct 18, 2013
- Abate by
- Nov 29, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace: a. On or about July 23, 2013, an employee who was required to wear NIOSH approved respirators had not received respirator training.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 325510)
More inspections in HI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339245052.